Loading...
Spreading operation 8
90
Spreading application higher on
one side than the other.
Hopper empties unevenly during
normal spreading.
Fertiliser bridging above the agitator
Remove fertiliser until the height of the protective grid on
the affected side.
Break up accumulated fertiliser with a wooden stick
through the bars of the protective grid.
Outlet blocked
See blockages of the metering openings
Defective agitator
Remove fertiliser until the height of the protective grid on
the affected side.
Open the metering slide and break up accumulated fertil-
iser with a wooden stick through the bars of the protective
grid so that the remaining fertiliser can run out of the out-
let.
Check the functionality of the agitator drive. See chapter
9.8: Checking the agitator drive, page 105
.
Metering slide set incorrectly
Empty the hopper of remaining fertiliser. See chapter
8.12: Discharging residual material, page 92
.
Check metering slide setting. See chapter 9.10: Metering
slide adjustment, page 109.
Irregular fertiliser feed to spread-
ing disc
Fertiliser bridging above the agitator
Remove fertiliser until the height of the protective grid on
the affected side.
Break up accumulated fertiliser with a wooden stick
through the bars of the protective grid.
Outlet blocked
See blockages of the metering openings
Defective agitator
Remove fertiliser until the height of the protective grid on
the affected side.
Open the metering slide and break up accumulated fertil-
iser with a wooden stick through the bars of the protective
grid so that the remaining fertiliser can run out of the out-
let.
Check the functionality of the agitator drive. See chapter
9.8: Checking the agitator drive, page 105
.
Spreading discs are fluttering.
Check cap nuts for tight fit and check threads.
Metering slide opens with difficulty
or not at all.
Metering slides do not move easily. Check for smooth
slide movement, check the lever and the joints, and im-
prove if necessary.
Fault Possible cause/action