EasyManua.ls Logo

Raymarine 150 - Page 25

Raymarine 150
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 Type 150/400 Autopilot System: Installation Guide
Step 3
* These specifications apply to the cabling for CR pump solenoids. Power the
CR pump motor separately, as specified in the CR pump installation guide.
Table 3-1: Recommended power supply cable sizes (stranded cables)
Cable length
(distribution panel to course computer)
Cable gauge
(AWG)
Copper area
(mm
2
)
Type 1 drive 12/24 V;
I/O drive; CR pump solenoids*
up to 3m (10ft)
up to 5m (16ft)
up to 7m (23ft)
up to 10m (32ft)
up to 16m (52ft)
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
2.5 mm
2
4 mm
2
6 mm
2
10 mm
2
16 mm
2
Type 2 drive 12 V
up to 5m (16ft)
up to 7m (23ft)
up to 16m (52ft)
10 AWG
8 AWG
6 AWG
6 mm
2
10 mm
2
16 mm
2
Type 2 drive 24 V
up to 3m (10ft)
up to 5m (16ft)
up to 10m (32ft)
up to 16m (52ft)
12 AWG
10 AWG
8 AWG
6 AWG
4 mm
2
6 mm
2
10 mm
2
16 mm
2
Type 3 drive 12 V
up to 5m (16ft)
up to 7m (23ft)
up to 16m (52ft)
8 AWG
6 AWG
4 AWG
10 mm
2
16 mm
2
25 mm
2
Type 3 drive 24 V
up to 5m (16ft)
up to 7m (23ft)
up to 16m (52ft)
10 AWG
8 AWG
6 AWG
6 mm
2
10 mm
2
16 mm
2
Table 3-2: Recommended power cable fuse and circuit breaker sizes
Drive unit Fuse (Amps)
Thermal over-current
circuit breaker (Amps)
Rotary, linear, hydraulic pump,
hydraulic linear
Type 1: 12 V and 24 V
Type 2: 12 V
Type 2: 24 V
Type 3: 12 V and 24 V
25 A
40 A
30 A
40 A
20 A
30 A
30 A
30 A
I/O drive 15 A 10 A
CR pump solenoids* 10 A 10 A
81173_3.book Page 16 Thursday, June 7, 2001 11:51 AM