26 ST60 Tridata Instrument Owners Manual
Stand alone instruments
Stand-aloneinstruments are not connected toSeaTalk and therefore need
to be connected to an alternative 12 V power source. Power cables are
available in 2 m and 9 m lengths.
To fit a power cable:
1. Ensure the intended power source is switched off. If you are using a
12 V battery, ensure the power cable is not connected to the battery.
2. Run the power cable from the instrument to a suitable 12 V dc power
source.
3. If the cable has not already been trimmed at the power supply end:
Cut the cable to length and trim back an appropriate amount of the
outer sheath.
Cut back and insulate the yellow wire.
4. Connect the screen to the power supply 0 V terminal.
5. Connect the red wire via a 3 A over-current circuit breaker to the
power supply +12 V terminal.
D4311-1
5 A fused,
12 V dc supply
(typically provided
by autopilot)
Red
Screen
Red
Screen
1234
Instruments
5 to 16
17
18
19
20
SeaTalk power connections
81040_1.book Page 26 Thursday, November 7, 2002 10:21 AM