Loading...
4.4Windsetup
Calibratingwindspeed
Youwillneedtobeunderway,withsufcientspacetoturnina
largeslowcircleunhindered.
Conditionsshouldbecalmorslightwaterandasteadybreeze.
WiththelistoftransducersavailabledisplayedfromtheTransducer
Setupmenu.
1.PressENTERtoproceedtothetransducersetupoptions.
2.SelectWindthenCalibrateVanefromtheavailableoptions.
3.PressENTERandfollowtheon-screeninstructionstocomplete
thecalibration.
Aligningthewindvane
Aligningthewindvaneensuresthatthewindanglereadingis
accurate.
Youwillneedtobeunderway,withsufcientspacetomaneuver
unhindered.
Conditionsshouldbecalmorslightwaterandasteadybreeze.
Headdirectlyintothewind,thenfollowtheinstructionsbelow.
WiththelistoftransducersavailabledisplayedfromtheTransducer
Setupmenu:
1.PressENTERtoproceedtothetransducersetupoptions.
2.SelectWindthenAlignVanefromtheavailableoptions.
3.Checkthatyouarestillheadingdirectlyintothewind,then
pressENTERtoacceptthealignmentandreturntotheWind
transducersetupmenu.
4.5Speedcalibration
Speedcalibrationinvolvesaligningthelogspeed(SpeedThrough
Water)totheSpeedoverground(SOG),underzerotideconditions.
Theobjectofspeedcalibrationistoensurethatthespeedreadings
attheinstrumentsaretrueindicationsoftheboatspeed.
Speedtransducerperformanceisaffectedbyitspositionand
water-owcharacteristicsatdifferentspeeds.Itisadvisabletocarry
outcalibrationatvariousspeedsacrosstherangeofyourboat.
Calibratingspeed(conventionaltransducers)
Youwillneedanaccuratespeedoverground(SOG)value,e.g.
determinedfromaGPSconnectedintoyourSeaT alksystem.
Youwillneedtobeunderway,withsufcientspacetomaneuver
unhindered.
Conditionsshouldbecalmwaterwithaslacktide.
Note:Itisimportantthatthereisnotide.Theaffectoftidal
currentwouldbetopreventanaccuratespeedcalibration.
WiththelistoftransducersavailabledisplayedfromtheTransducer
Setupmenu:
1.PressENTERtoproceedtothetransducersetupoptions.
2.SelectSpeedthenCalibrationfromtheavailableoptions.
3.Calibrateeachspeedasfollows,startingwiththelowest: