INSTALLATION & OPERATING
INSTRUCTIONS
Gas-Fired
Pool & Spa
Heater
Catalog No. 6000.59U Effective: 10-06-10 Replaces: 06-10-10 P/N 241236 Rev. 22
WARNING: If these instructions are not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas sup-
plier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
This manual should be maintained in legible condition and kept adjacent to the heater or in a safe place for future
reference.
Atmospheric Models
206A, 266A, 336A & 406A
Lo NOx Models
207A, 267A, 337A & 407A
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.

Table of Contents

Other manuals for Raypak 267A

Questions and Answers

  • P
    pdavisAug 27, 2025
    What to do if Raypak 267A Gas Heater combustion fan is not running?
    • I
      ilyonsAug 27, 2025
      If the combustion fan in your Raypak Gas Heater isn't running, it could be due to a few reasons. The fan relay might be faulty, requiring replacement. There could be a loose connection or a failed motor in the fan itself. A burned motor due to incorrect wiring could also be the cause, necessitating blower replacement. Finally, the air pressure switch might need replacing.
  • T
    Taylor SmithAug 27, 2025
    What to do if my Raypak 267A Gas Heater takes too long to heat pool or spa?
    • M
      morrismarkAug 27, 2025
      If your Raypak Gas Heater is taking too long to heat your pool or spa, consider these potential causes: * The heater might be undersized. Calculate the heating capacity of the heater using the formula: Heater output (BTUH) = Pool gallonage x 8.33, or refer to the heater sizing chart. * The filter might not be running long enough; reset the time clock. * The filter could be dirty; clean the filter. * The gas line or meter may be undersized; refer to the installation instructions.
  • A
    ashleymorrisAug 25, 2025
    What to do if the combustion fan is not running on my Raypak Gas Heater?
    • J
      Jacob ChavezAug 26, 2025
      If the combustion fan in your Raypak Gas Heater is not running, it could be due to several reasons. The fan relay might be faulty, so replace it. There might be a loose connection or a failed motor in the fan itself. A burned motor due to incorrect wiring could also be the cause, so replace the blower. Finally, the air pressure switch might need replacement.
  • J
    Joshua PenningtonAug 25, 2025
    Why does my Raypak 267A have a yellow lazy flame?
    • J
      Jenna JohnsonAug 25, 2025
      If your Raypak Gas Heater is producing a yellow, lazy flame, it could be due to low gas pressure, in which case you should adjust the gas pressure. Another potential cause is insects or debris clogging the burner intake ports; if this is the case, clean the burners.

Summary

PART ONE OWNERS OPERATING INSTRUCTIONS

START-UP PROCEDURES

Steps and checks before operating the pool or spa heater.

LIGHTING AND SHUT-OFF PROCEDURES (MILLIVOLT & ELECTRONIC IGNITION)

Guides for lighting and shutting down millivolt and electronic ignition models.

CAUTIONS, MAINTENANCE, AND COLD WEATHER OPERATION

Safety guidelines, routine maintenance, and cold weather operations.

WINTERIZING PROCEDURES

Procedures to prepare the heater for winter shutdown.

PART TWO INSTALLATION AND SERVICE INSTRUCTIONS

RECEIVING EQUIPMENT AND GENERAL SPECIFICATIONS

Inspecting equipment upon arrival and technical specifications.

INSTALLATION REQUIREMENTS, CLEARANCES, AND GAS;VENTILATION

Installation guidelines, clearances, and air/gas requirements.

DIMENSIONS, WIRING, AND CONTROL OPERATIONS

Physical dimensions, electrical wiring, and thermostat operations.

SERVICING, TROUBLESHOOTING, AND REPLACEMENT PARTS

Procedures for servicing, diagnosing issues, and ordering parts.

Raypak 267A Specifications

General IconGeneral
Model267A
CategoryGas Heater
Fuel TypeNatural Gas or Propane
Water Connection2" NPT
Heat ExchangerCopper
Ignition TypeElectronic
Efficiency80%
Thermal Efficiency80%