INSTALLATION INSTRUCTIONS (continued)
FLUE TERMINATION LOCATION
Flue terminations shall not be recessed in walls or sidings.
EXTREMELY IMPORTANT: In heavy snow areas take extra care to prevent blocking
flue termination with snow removal equipment.
Flue gases exiting flue terminals are very hot and must not be restricted to assure fireplace
combustion is not affected.
Do not place, build any obstruction, plant any bushes or for any reason attempt to conceal
the flue termination. To do so will affect the operation of the fireplace and may be hazardous.
This unit must always vent directly to outdoors.
GAS CONNECTION – 15mm (1/2”) Compression union
ELECTRICAL CONNECTION – 3 Pin 10 Amp GPO plug
POWER RATING OF APPLIANCE – 230V 50Hz 0.55Amp