PROBLEM SOLUTION
Water is leaking from unit when dispensing 1. Faulty air pump check valve.
2. Drain tube plug is not installed.
3. Internal leak in plumbing circuit. Remove panels and
observe for signs of leakage (water drops or residual
calcium deposits)
Display indicates replace reservoir Reservoir not installed properly. Ensure reservoir is
installed flush with left side of brewer to ensure
engagement of presence switch.
Display indicates low or no water. 1. Missing level float in reservoir. Replace float in
reservoir.
2. Water supply turned off to machine. Restore water
supply to machine.
3. Machine is waiting manual refill. Refill reservoir
manually.
Brew chamber opens while brewing 1. Capsule holder is not snapped into carrier correctly.
Ensure capsule holder is completely snapped into
carrier.
2. Brew chamber was not fully latched. Ensure the latch
is snapped into position during closure.