Error Codes
EngineeringDepartment
ErroscodesforMotherParker'sSingleCupBrewer
TOBEPERFORMEDBYQUALIFIEDSERVICETECHNICIAN
QRcode SOURCEPROBLEM PROBABLECAUSE CORRECTIVEACTION
1 TankHeattimeout Heaterfailure
Measureresistanceacrossheater
leads.Ifopen,replacetankassem‐
bly.
Harnessopens
Checkconductivitybe tweenheater
leadsandboard.Replaceif
needed.
Triacboardfailure Replacetriacboard
Limitswitchopen Replacetankassembly
Controlboardfailure Replacecontrolboard
2 No/lowwaterflow Pumpfailure
Apply24VACtopumptocheck
operation.Replaceifneeded.
Harnessopens
Checkconductivitybe tweenpump
leadsandboard.Replaceif
needed.
Controlboardfailure Replacecontrolboard
3 TankOver‐Temperature Scalebuildupintankassembly
Delimetankor
replacetankif
needed.
Triacboardfailure Replacetriacboard
Useofhotwaterinreservoir Checkuserinteraction
Hotwaterbypassingintoreservoir
whilebrewing
Checkhighpressurebypasscheck
valve.Pulltubeoffoftopoftank
andblowairtowardsreservoir.If
aircomesout,replace.
Pressureis
11PSInominal.
4 Openthermistor Brewerwillnotoperateatall
Checkthermistorharnessconnec‐
tion.Measurethermistorresis‐
tance30K@75F.Replacetank
assemblyifneeded.
5 Generalfault Various
Checklatestservicematerialson
website
ENGLISH