Beijing Reci Laser Technology Co., Ltd
User Guide for FCA Series Hand Laser Welding System
4.7.2 Sequence of operations
(1) If you need to connect a wire feeder, please connect the wire feeder that meets the
requirements to the corresponding port on the rear panel of the laser before powering on.
(2) Turn on the power supply of the device, turn on the air switch on the rear panel of the
device, and wait for the initialization of the device for 10 seconds.
(3) Turn on the laser output function through the "Laser en" in the monitoring interface of the
PC.
(4) Input the required process parameters through the setting interface of the PC.
(5) Touch to set the laser "Work mode" to series or spot welding through the monitoring
interface of the PC.
(6) Clamp the workpiece clamp on the workpiece or plate to be processed.
(7) Short the weld head and the workpiece clamp, and simulate the processing process through
the red indicator light.
(8) Press the button of the weld head, and turn on the laser according to the set parameters.
(9) After the processing is completed, release the button of the weld head, and turn off the
laser according to the set parameters.
(10) If the current parameter is suitable for the current workpiece, the parameter can be
saved on the settings interface of the PC, and it can be selected directly next time.
(11) If you need to adjust the process parameters, repeat steps (3) ~ (7).
Notice:
The parameter storage and selection can only be 2 digits, and the previously saved parameters
will be overwritten when the storage name is repeated.