Operating instructions DFA 127 Full Power Rev. B 11/2006 Page 19 of 20
Status and fault signals
Status 60: Parameter memory (EEPROM) defective
Change control unit
Reset by service fitter
Status 61: SSK active longer than 60 s
Automatically reset if in order, or by service fitter
Status 62: BDE has no priority
Because a higher-level signal is present
Automatically reset on release of BDE-button
Status 72: Slave connection
Master has no connection to Slave operator
Reset by service fitter
Status 88: Difference parameter
The common parameters of M/S operators do not correspond to
each other.
Reset by service fitter
Status 89: Master connection
Slave has no connection to master operator
Reset by service fitter
Status 90: Railbeam active > 60 sec.
Automatically reset if everything is in order, or by service fitter
Status 91: Bodyguard active > 60 sec.
Automatically reset if everything is in order, or by service fitter
Status 92: STG relay defective
Replacement by service fitter
Status 93: Overvoltage 24 V (from 27V)
Status 94: Spring calibration
Automatic reset
Status 95: Error in sense of rotation
Status 96: EEPROM void
Status 99: Operator rotates
The grease in the gear will be dispersed.
Automatic reset
Status 105: Test brake
Automatic reset