EasyManuals Logo

red lion CUB 5P Installation Guide

red lion CUB 5P
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Install CUB5P- A
Drawing No. LP1133
Effective 06/2022
Model CUB
®
5P - Miniature Electronic
5-Digit Process Meter
Installation Guide
1
See the Red Lion website at www.redlion.net for full user manual.
SAFETY SUMMARY
All safety related regulations, local codes as well as instructions
that appear in this document or on equipment must be observed
to ensure personal safety and to prevent damage to either the
device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should
ever be designed to be responsible for the maintenance of
personnel safety or consequential equipment not equipped with
safeguards. Red Lion disclaims any responsibility for damages,
either direct or consequential, that result from the use of this
equipment in a manner not consistent with these specifications.
ORDERING INFORMATION
DESCRIPTION PART NUMBER
Process Meter with Reflective Display CUB5PR00
Process Meter with Backlight Display CUB5PB00
SPECIFICATIONS
1. POWER: Input voltage range is +9 to +28 VDC with short
circuit and input polarity protection. Must use an RLC model
MLPS or an NEC Class 2 or Limited Power Source (LPS) rated
power supply.
MODEL NO. DISPLAY COLOR
INPUT CURRENT
@ 9 VDC
WITHOUT
CUB5RLY0
INPUT
CURRENT @
9 VDC WITH
CUB5RLY0
CUB5PR00 --- 10 mA 40 mA
CUB5PB00 Red (max intensity) 85 mA 115 mA
CUB5PB00 Green (max intensity) 95 mA 125 mA
2. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits
CUB5PR00: Reflective LCD with full viewing angle
CUB5PB00: Transmissive LCD with selectable red or green
LED backlight, viewing angle optimized. Display color change
capability with output state when using an output module.
3. INPUT RANGES: Jumper Selectable
0 to 10 V, 0(4) to 20 mA, 0 to 50 mA
4. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5PR00: -35 to 75°C
Operating Temperature Range for CUB5PB00 depends on
display color and intensity level as per below:
INTENSITY LEVEL TEMPERATURE
Red Display
1 & 2 -35 to 75°C
3 -35 to 70°C
4 -35 to 60°C
5 -35 to 50°C
Green Display
1 & 2 -35 to 75°C
3 -35 to 65°C
4 -35 to 50°C
5 -35 to 35°C
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
0.13 [3.3]
[43.4]
1.71
2.95 [74.9]
SEL
0.15 [3.8]
1.54 [39.1]
RST
1.29 [32.8]
2.62 [66.6]
1.29
[32.8]
DIMENSIONS In inches [mm]
Note: Recommended minimum clearance (behind the panel) for mounting
clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
C
C
US LISTED
US LISTED
U
L
R
IND. CONT. EQ.
E137808

Other manuals for red lion CUB 5P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the red lion CUB 5P and is the answer not in the manual?

red lion CUB 5P Specifications

General IconGeneral
Brandred lion
ModelCUB 5P
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals