THE APOLLO INTELLIGENT METER SERIES
MODEL IMP INSTRUCTION MANUAL
IMPCVR.QXD 7/9/02 1:22 PM Page 1

Questions and Answers

  • J
    Jeffery RichardsAug 2, 2025
    Why is my red lion Measuring Instruments display blank?
    • J
      Joseph MooreAug 2, 2025
      A blank display on your Red Lion Measuring Instruments device typically indicates a power issue. This could be due to the power being off, the wiring being improperly connected, or a brown-out. To resolve this, check the wiring and verify that the device is receiving adequate power.
  • E
    Eric VazquezAug 6, 2025
    What to do if my red lion Measuring Instruments display shows '......'?
    • J
      Javier GarciaAug 6, 2025
      If your Red Lion Measuring Instruments display shows '......', it usually means the input display is out of range or there has been a loss of data setups. You should check the unit scaling and data setups. Also, check for any electrical disturbances and try disconnecting and reconnecting the power.
  • J
    James BurgessAug 10, 2025
    Why is my red lion IMP display jittery?
    • J
      Joseph Vega DDSAug 10, 2025
      A jittery display on your Red Lion Measuring Instruments device is often caused by electrical noise in the process or signal lines, or the process itself being unstable. Try these steps to resolve the issue: 1. Increase digital filtering. 2. Increase the display rounding increment. 3. Re-route the signal wires. 4. If the process is inherently unstable, dampen the process to eliminate oscillations.
  • D
    Daniel MckenzieAug 14, 2025
    Why is my red lion Measuring Instruments display flashing?
    • J
      Joseph LoganAug 15, 2025
      A flashing display on your Red Lion Measuring Instruments indicates a totalizer overflow. To fix this, reset the totalizer.
  • M
    mooneyabigailAug 19, 2025
    What does 'PPPPPP' mean on my red lion IMP display and how to fix it?
    • J
      John BarnesAug 19, 2025
      If your Red Lion Measuring Instruments display shows 'PPPPPP', it indicates a program data error. Press the “P” button and check the data set-ups.
  • J
    Jordan PenaAug 23, 2025
    Why does my red lion IMP Measuring Instruments display wander?
    • C
      Caleb PattonAug 23, 2025
      A wandering display on your Red Lion Measuring Instruments typically indicates a loss of data setups. To resolve this, check the data setups, check for electrical disturbances, and try disconnecting and reconnecting the power.
  • T
    Timothy ParkerAug 27, 2025
    What does 'ULULUL' mean on my red lion IMP display and how to fix it?
    • B
      Brandy ShermanAug 27, 2025
      If the display shows “ULULUL” on your Red Lion Measuring Instruments, it means there is an input underload (negative overload). Check the input levels.

Summary

SAFETY INFORMATION

SAFETY SUMMARY

General safety precautions to ensure personal safety and prevent equipment damage.

DEFINITION OF TERMS

Defines installation categories for overvoltage protection.

GENERAL DESCRIPTION

THEORY OF OPERATION

Explains the microprocessor-based A/D conversion and signal processing.

PROGRAMMING THE IMP

PROGRAMMING OVERVIEW AND BASIC STEPS

Introduces programming mode, modules, and basic operations.

PROGRAMMING MODULE #1 - SCALE BY SIGNAL LEVEL METHOD

SIGNAL LEVEL SCALING PROCEDURE

Details steps for scaling using signal levels and display values.

PROGRAMMING MODULE #2 - SCALE BY KEY-IN METHOD

KEY-IN SCALING PROCEDURE

Details steps for scaling by manually entering signal and display values.

PROGRAMMING MODULE #3 - PROGRAM FUNCTIONS ACCESSIBLE W;FRONT PANEL LOCKOUT

FRONT PANEL LOCKOUT CONFIGURATION

Configures accessible functions when PGM. DIS. pin is connected to common.

PROGRAMMING MODULE #4 - PROGRAM DIGITAL FILTER AND REMOTE INPUT

DIGITAL FILTERING AND REMOTE INPUT FUNCTIONS

Configures filtering and functions of E1/E2-CON pins.

PROGRAMMING MODULE #5 - PROGRAM TOTALIZER;INTEGRATOR

TOTALIZER SETUP AND CONFIGURATION

Configures decimal point, time base, scale factor, and low-end cutout.

PROGRAMMING MODULE #6 - PROGRAM ALARM;SETPOINT

ALARM AND SETPOINT CONFIGURATION

Sets alarm tracking, display, reset, assignment, value, hysteresis, and action.

PROGRAMMING MODULE #7 - PROGRAM SERIAL COMMUNICATIONS

SERIAL COMMUNICATION SETUP

Configures baud rate, address, print function, and transmission type.

PROGRAMMING MODULE #8 - PROGRAM RE-TRANSMITTED ANALOG OUTPUT

ANALOG OUTPUT SCALING AND CONFIGURATION

Scales the 4-20mA or 0-10VDC analog output.

PROGRAMMING MODULE #9 - SERVICE OPERATIONS

SERVICE OPERATIONS AND DIAGNOSTICS

Procedures for accessing service operations and hardware diagnostics.

FACTORY CONFIGURATION

PROGRAMMING EXAMPLE

PRESSURE MONITORING EXAMPLE

EXCITATION (Optional)

TOTALIZER;LINEARIZER;PEAKWALLEY;TARE (OPTIONAL)

TOTALIZER OPERATION AND SETUP

Explains the totalization feature and its settings.

LINEARIZER FEATURE

PEAK;VALLEY DETECTION

TARE FUNCTION

ALARMS OPTION

20 mA CURRENT LOOP SERIAL COMMUNICATIONS (Optional)

SERIAL COMMUNICATIONS GENERAL DESCRIPTION

Explains the serial communication option.

COMMUNICATION FORMAT AND BAUD RATES

Describes data format and baud rates.

SENDING COMMANDS TO THE IMP

SERIAL COMMAND STRING EXAMPLES

RECEIVING DATA FROM THE IMP

CURRENT LOOP INSTALLATION

WIRING CONNECTIONS

Instructions for connecting the current loop.

SERIAL TERMINAL DESCRIPTIONS

Describes the function of each serial terminal.

SERIAL COMMUNICATIONS EXAMPLES

CONNECTING TO AN RLC PRINTER

Example setup for serial communication with a printer.

PROCESS CONTROLLING SYSTEM EXAMPLE

RE-TRANSMITTED ANALOG OUTPUT (OPTIONAL)

ANALOG OUTPUT DIAGRAMS

Illustrates normal and reverse acting analog output.

ANALOG OUTPUT CALIBRATION

APPENDIX “A” - INSTALLATION & CONNECTIONS

INSTALLATION ENVIRONMENT AND PANEL MOUNTING

Guidelines for installation location and panel mounting.

EMC INSTALLATION GUIDELINES

WIRING CONNECTIONS

POWER, USER INPUT, AND OUTPUT WIRING

Connects power, digital inputs, and outputs.

SIGNAL WIRING

APPENDIX “B” - SPECIFICATIONS AND DIMENSIONS

APPENDIX “B” - SPECIFICATIONS AND DIMENSIONS

SERIAL COMMUNICATIONS, ALARMS, AND ANALOG OUTPUT SPECS

Details specifications for optional features.

CERTIFICATIONS AND COMPLIANCES

Lists safety and compliance standards met by the unit.

ELECTROMAGNETIC COMPATIBILITY

APPENDIX “C” - LINEARIZER PROGRAM

APPENDIX “D” - TROUBLESHOOTING GUIDE

APPENDIX “E” - PROGRAMMABLE FUNCTIONS

APPENDIX “F” - USERS PROGRAMMING VALUES CHART

APPENDIX “G” - ORDERING INFORMATION

red lion IMP Specifications

General IconGeneral
Protocols SupportedDNP3
ConnectivityEthernet, Serial
MountingDIN Rail
Input Typedigital
DisplayLCD
CommunicationEthernet, RS-232, RS-485