MPAX PERSONALITY MODULE SELECTOR GUIDE FOR LPAX
Our large displays have various input options, determined by the installation of a MPAX personality module. These MPAX
modules are based on standard PAX panel meters, and use the same data sheet as the PAX meter for specifications and wiring.
About the MPAX Input Modules
The MPAX Module serves as the input to the LPAX Display. There are several different modules to cover a variety of inputs. The
MPAX module provides input scaling which allows the LPAX to display most any engineering unit. Once the MPAX is inserted into
the LPAX, the unit has the same functions and capabilities of our PAX Series Intelligent Panel Meters. A full set of PAX
programming instructions will be included with the MPAX Module.
Note: The MPAX provides the operating power for the LPAX, therefore you must select either the AC or DC MPAX corresponding
with your application and available power.
Selecting Your Display Components
To build a complete display unit, you will need an LPAX and an MPAX Input Module. The LPAX is only a display and will not
operate without an MPAX Module. Please use the following chart to identify the appropriate MPAX Module (including supply
power) and LPAX Display that will satisfy your application.
MPAX Modules for LPAX5 (Analog units)
MPAX Modules for LPAX6 (Digital units)
MPAX MODULES *
SIGNAL TYPE INPUT RANGES
85-250 VAC
11 to 36 VDC/ 24 VAC
LPAX DISPLAYS
Universal DC Inpu ts
DC Voltage 200 m V, 2 V, 20 V, 300 V
DC Current 200 µA, 2 mA, 20 mA, 200 mA, 2 Amp
Resistance 100 ohm, 1000 ohm, 10 K ohm
MPAXD000 MPAXD010 LPAX0500
Process Inpu ts 0-20 mA or 0-10 VDC MPAXP000 MPAXP010 LPAX0500
Temperature Inpu ts MPAXT000 MPAXT010 LPAX0500
Strain Gage/Load Cell 24 mV or 240 mV MPAXS000 MPAXS010 LPAX0500
True RMS AC
Voltage/Current
AC Voltage 200 m V, 2 V, 20 V, 300 V
AC Current 200 uA, 2 mA, 20 mA, 200 mA, 5 Amp
MPAXH000 N/A LPAX0500
SETPOINT
YES
MPAX MODULES*
YES
YES
SIGNAL TYPE
YES
85-250 VAC
11 to 36 VDC / 24 VAC
LPAX
DISPLAYS
Count/Rate/Serial Slave
COMMS
MPAXI000
MPAXI010
LPAX0600
Count
YES
MPAXC000 MPAXC010 LPAX0600
Rate
-
MPAXR000 MPAXR010 LPAX0600
Clock/ Timer
-
MPAXCK00
††
MPAXCK10
††
LPAXCK00**
YES
ANALOG
YES
-
-
-
REAL-TIME
CLOCK
-
-
-
YES
OPTIONAL PLUG-IN CARD COMPATIBILITY
YESTime r
MPAXTM00
††
MPAXTM10
††
LPAXCK00**
YES - -
MPAX Modules for LPAXDA (Dual Analog Unit)
MPAX MODULES *
SIGNAL TYPE INPUT RANGES
85-250 VAC
11 to 36 VDC/ 24 VAC
LPAX DISPLAY
Dual Process Inputs 0-20 mA or 0-10 VDC MPAXDP00 MPAXDP10 LPAXDA00
Thermocouples -T , E, J, K, R, S, B, N, C,
or Custom Scaling RTDs - 100 ohm Pt (platinum) 385/392,
120 ohm Nickel 672, or 10 ohm Copper 427

Questions and Answers:

red lion PAXD Series Specifications

General IconGeneral
Brandred lion
ModelPAXD Series
CategoryMeasuring Instruments
LanguageEnglish

Summary

ORDERING INFORMATION

GENERAL METER SPECIFICATIONS

2. POWER

Details power requirements for AC and DC versions of the meter.

MODEL PAXD - UNIVERSAL DC INPUT

MODEL PAXP - PROCESS INPUT

MODEL PAXH - AC TRUE RMS VOLT AND CURRENT

MODEL PAXS - STRAIN GAGE INPUT

MODEL PAXT - THERMOCOUPLE AND RTD INPUT

OPTIONAL PLUG-IN OUTPUT CARDS

2.0 SETTING THE JUMPERS

Input Range Jumper

Explains how to select the proper input range using the jumper.

3.0 WIRING THE METER

EMC INSTALLATION GUIDELINES

Offers guidelines for ensuring electromagnetic compatibility during installation.

3.2 INPUT SIGNAL WIRING

PAXD INPUT SIGNAL WIRING

Shows wiring diagrams for various PAXD input signal types.

PAXP INPUT SIGNAL WIRING

Illustrates wiring diagrams for various PAXP input signal types.

PAXH INPUT SIGNAL WIRING

PAXS INPUT SIGNAL WIRING

PAXT INPUT SIGNAL WIRING

3.3 USER INPUT WIRING

4.0 REVIEWING THE FRONT BUTTONS AND DISPLAY

5.0 PROGRAMMING THE METER

PROGRAMMING MODE

Explains the two programming modes: Full and Quick.

PROGRAMMING MODE ENTRY (PAR KEY)

Describes how to enter the programming mode.

5.1 MODULE 1 - SIGNAL INPUT PARAMETERS (1-INP)

PAXD INPUT RANGE

Details input range selections for PAXD.

PAXT INPUT TYPE

Lists available input types for PAXT, including RTD and custom options.

PAXS INPUT RANGE

Details input range selections for PAXS.

PAXH INPUT RANGE

Details input range selections for PAXH.

5.2 MODULE 2 - USER INPUT AND FRONT PANEL FUNCTION KEY PARAMETERS (2-FAC)

ZERO (TARE) DISPLAY

Allows zeroing the input display value for applications like weighing.

RELATIVE/ABSOLUTE DISPLAY

Switches the input display between relative and absolute values.

PROGRAMMING MODE LOCK-OUT

Locks programming mode, allowing access only with a security code.

HOLD DISPLAY

RESET MAXIMUM

Resets the maximum reading to the current input display value.

HOLD ALL FUNCTIONS

RESET, SELECT, ENABLE MAXIMUM DISPLAY

Manages the maximum value display and detection.

SYNCHRONIZE METER READING

SELECT MINIMUM DISPLAY

Selects the minimum display value, holding it until released.

STORE BATCH READING IN TOTALIZER

RESET MINIMUM

Resets the minimum reading to the current input display value.

SELECT TOTALIZER DISPLAY

RESET, SELECT, ENABLE MINIMUM DISPLAY

Manages the minimum value display and detection.

RESET TOTALIZER

RESET MAXIMUM AND MINIMUM

Resets both maximum and minimum readings simultaneously.

RESET AND ENABLE TOTALIZER

SETPOINT SELECTIONS

5.3 MODULE 3 - DISPLAY AND PROGRAM LOCK-OUT PARAMETERS (3-LOC)

MAXIMUM DISPLAY LOCK-OUT*

Locks out the maximum display from view.

MINIMUM DISPLAY LOCK-OUT*

Locks out the minimum display from view.

TOTALIZER DISPLAY LOCK-OUT*

Locks out the totalizer display from view.

SP-1 SP-2 SP-3 SP-4 SETPOINT ACCESS*

Controls access to setpoint displays for modification.

PROGRAM MODE SECURITY CODE*

Sets a security code to protect programming mode access.

5.4 MODULE 4 - SECONDARY FUNCTION PARAMETERS (4-SEC)

PAXS: AUTO-ZERO TRACKING

Enables automatic compensation for zero drift.

5.5 MODULE 5 - TOTALIZER (INTEGRATOR) PARAMETERS (5-TOT)

5.6 MODULE 6 - SETPOINT (ALARM) PARAMETERS (6-SP)

SPSEL - SELECT SETPOINT

Selects which setpoint to configure.

5.7 MODULE 7 - SERIAL COMMUNICATIONS PARAMETERS (1-SR)

5.8 MODULE 8 - ANALOG OUTPUT PARAMETERS (8-Out)

5.9 MODULE 9 - FACTORY SERVICE OPERATIONS (9-FC5)

RESTORE FACTORY DEFAULTS

Resets all user settings to factory defaults.

CALIBRATION

General information regarding meter calibration.

PAXP - Input Calibration

Step-by-step guide for calibrating PAXP input ranges.

PAXD - Input Calibration

Step-by-step guide for calibrating PAXD input ranges.

PAXH - Input Calibration

Step-by-step guide for calibrating PAXH input ranges using DC signals.

AC Couple Offset Calibration - PAXH

PAXS - Input Calibration

Guide to calibrating PAXS input ranges, including signal connection.

PAXT - Input Calibration

Provides calibration steps for PAXT input types.

10 OHM RTD Range Calibration

Details calibration procedure for 10 ohm RTD ranges.

100 OHM RTD Range Calibration

Details calibration procedure for 100 ohm RTD ranges.

THERMOCOUPLE Range Calibration

Step-by-step guide for calibrating thermocouple ranges.

ICE POINT Calibration

Procedure for calibrating the ice point compensation.

ANALOG OUTPUT CARD CALIBRATION

Steps to calibrate the analog output card.

TROUBLESHOOTING

NO DISPLAY

Troubleshoots issues related to the display not turning on.

PROGRAM LOCKED-OUT

Provides steps to resolve programming lock-out issues.

INCORRECT INPUT DISPLAY VALUE

Addresses problems with inaccurate input display readings.

"OLOL" in DISPLAY (SIGNAL HIGH)

Troubleshoots display showing "OLOL" indicating a high signal.

"ULUL" in DISPLAY (SIGNAL LOW)

Troubleshoots display showing "ULUL" indicating a low signal.

ERROR CODE (Err 1-4)

Explains how to handle error codes displayed by the meter.

PARAMETER VALUE CHART

2-FAC User Input and Function Key Parameters

3-LOC Display and Program Lockout Parameters

MAX DISPLAY LOCKOUT

Setting to lock the maximum display.

MIN DISPLAY LOCKOUT

Setting to lock the minimum display.

TOTAL DISPLAY LOCKOUT

Setting to lock the totalizer display.

SECURITY CODE

Parameter for setting the programming mode security code.

4-SEC Secondary Function Parameters

PAXS: AUTO-ZERO DELAY

Sets the delay for PAXS auto-zero tracking.

PAXS: AUTO-ZERO BAND

Sets the band for PAXS auto-zero tracking.

5-TOT Totalizer (Integrator) Parameters

6-SP Setpoint (Alarm) Parameters

SPSEL - SETPOINT SELECT

Selects which setpoint to configure.

ACE - SETPOINT ACTION

Defines setpoint action (e.g., output logic, reset).

SP-- SETPOINT VALUE

Sets the numerical value for setpoint alarms.

7-SR Serial Communication Parameters

8-Out Analog Output Parameters

9-FC5 Factory Setting Parameters

MODEL LPAX-5 DIGIT LARGE PAX DISPLAY FOR ANALOG INPUTS

SAFETY SUMMARY

Essential safety regulations and warnings for the LPAX Display.

7. ENVIRONMENTAL CONDITIONS

OPTIONAL PLUG-IN CARDS AND ACCESSORIES

1.0 ASSEMBLING THE DISPLAY

Installing the MPAX

Detailed steps for installing the MPAX module into the LPAX case.

2.0 INSTALLING THE DISPLAY

3.0 WIRING AND PROGRAMMING THE DISPLAY

Related product manuals