-1-
Inside US: +1 (877) 432-9908 Bulletin No. PAXLA-E
Outside US: +1 (717) 767-6511 Drawing No. LP0722
www.redlion.net Released 2018-01-19
3.60 (91.4)
(96.5)
3.80
1.95
(49.5)
(2.5)
.10
(104.1)
4.10
(44.5)
1.75
PAR
9
1
3
2
4
5
6
7
8
10
13
11
12
14
15
SEL RST
P
S
1P
S
2
8.8.8.8.8
X
M
A
IMN
V
GENERAL DESCRIPTION
The PAXLA is a versatile meter available as a DC volt, current, or
process meter with scaling and dual Form C relay outputs. The meter is
programmed through the front panel buttons and the use of jumpers. The
RST button can also function as a front panel display reset.
Once the front panel programming is complete, the buttons can be
disabled by a user input setting. The meter has been specifically
designed for harsh industrial environments. With a NEMA 4X/IP65
sealed bezel and extensive testing to meet CE requirements, the meter
provides a tough yet reliable application solution.
SAFETY SUMMARY
All safety regulations, local codes and instructions that appear in this
and corresponding literature, or on equipment, must be observed to
ensure personal safety and to prevent damage to either the instrument
or equipment connected to it. If equipment is used in a manner not
specified by the manufacturer, the protection provided by the equipment
may be impaired.
ORDERING INFORMATION
MODEL NO. DESCRIPTION PART NUMBER
PAXLA
Volt/Current/Process Meter with Dual Relay Output PAXLA000
UL Listed Volt/Current/Process Meter with Dual
Relay Output
PAXLA0U0
PAXLBK Unit Label Kit Accessory PAXLBK10
SPECIFICATIONS
1. DISPLAY: 5 digit, 0.56" (14.2 mm) intensity adjustable Red LED
(-19999 to 99999)
2. POWER REQUIREMENTS:
AC POWER: 50 to 250 VAC 50/60 Hz, 12 VA
Isolation: 2300 Vrms for 1 min. to all inputs and outputs
DC POWER: 21.6 to 250 VDC, 6 W
DC Out: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/
VDC
+24 VDC @ 50 mA if input voltage is less than 50 VDC
3. INPUT RANGES: Jumper Selectable
D.C. Voltages: 200 mV, 2 V, 20 V, 200 V, 10 V
INPUT
RANGE
ACCURACY @
23 °C LESS
THAN 85% RH
INPUT
IMPEDANCE
MAX
INPUT
SIGNAL
RESOLUTION
TEMP.
COEFFICIENT
200 mV 0.1% of span
1.033 MΩ
75 VDC 10 µV 70 ppm /°C
2 V 0.1% of span
1.033 MΩ
75 VDC 0.1 mV 70 ppm /°C
10 V 0.1% of span
1.033 MΩ
250 VDC 1 mV 70 ppm /°C
20 V 0.1% of span
1.033 MΩ
250 VDC 1 mV 70 ppm /°C
200 V 0.1% of span
1.033 MΩ
250 VDC 10 mV 70 ppm /°C
D.C. Currents: 200 µA, 2 mA, 20 mA, 200 mA
INPUT
RANGE
ACCURACY @
23 °C LESS
THAN 85% RH
INPUT
IMPEDANCE
MAX
INPUT
SIGNAL
RESOLUTION
TEMP.
COEFFICIENT
200 µΑ 0.1% of span
1.111 KΩ
15 mA 10 nA 70 ppm /°C
2 mA 0.1% of span
111 Ω
50 mA 0.1 µA 70 ppm /°C
20 mA 0.1% of span
11 Ω
150 mA 1 µA 70 ppm /°C
200 mA 0.1% of span
1 Ω
500 mA 10 µA 70 ppm /°C
D.C. Process: 4 to 20 mA, 1 to 5 VDC, 0/1 to 10 VDC
INPUT RANGE SELECT RANGE
4 - 20 mA Use the 20 mA range
1 - 5 VDC Use the 10V range
1 - 10 VDC Use the 10V range
5 DIGIT, 0.56" HIGH RED LED DISPLAY
PROGRAMMABLE SCALING AND DECIMAL POINTS
PROGRAMMABLE USER INPUT
DUAL 5 AMP FORM C RELAY
UNIVERSALLY POWERED
NEMA 4X/IP65 SEALED FRONT BEZEL
OPTIONAL CUSTOM UNIT OVERLAY W/ BACKLIGHT
MINIMUM AND MAXIMUM DISPLAY CAPTURE
Model PAXLA - PAX Lite DC Volt/Current/Process Meter
DIMENSIONS In inches (mm)
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
For Model No. PAXLA0U0 Only
C
US LISTED
U
L
R
PROC. CONT. EQ.
E179259