EasyManua.ls Logo

red lion PAXLA - Installing the Meter

red lion PAXLA
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-2-
Drawing No. LP0722 Released 2018-01-19
4. OVERRANGE/UNDERRANGE INDICATION:
Input Overrange Indication: “OLOL”.
Input Underrange Indication: “ULUL”.
Display Overrange/Underrange Indication: “.....”/“-.....
5. A/D CONVERTER: 16 bit resolution
6. UPDATE RATES:
A/D conversion rate: 20 readings/sec.
Display update: 500 msec min.
7. USER INPUT:
User Input: Software selectable pull-up (24.7 K) or pull-down resistor
(20 K) that determines active high or active low input logic.
Trigger levels: V
IL
= 1.0 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Response Time: 5 msec typ.; 100 msec debounce (activation and
release)
8. MEMORY: Nonvolatile E
2
PROM retains all programming parameters
when power is removed.
9. OUTPUT:
Type: Dual FORM-C relay
Isolation To Sensor & User Input Commons: 1400 Vrms for 1 min.
Working Voltage: 150 Vrms
Contact Rating: 5 amps @ 120/240 VAC or 28 VDC (resistive load),
1/8 H.P. @ 120 VAC (inductive load)
Life Expectancy: 100,000 minimum operations
Response Time:
Turn On Time: 4 msec max.
Turn Off Time: 4 msec max.
10. ENVIRONMENTAL CONDITIONS:
Operating temperature: 0 to 50 °C
Storage temperature: -40 to 70 °C
Operating and storage humidity: 0 to 85% max. RH (non-condensing)
Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g.
Shock to IEC 68-2-27: Operational 30 g (10 g relay).
Altitude: Up to 2,000 meters
11. CONNECTIONS: High compression cage-clamp terminal block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
12. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use.
IP20 Touch safe. Installation Category II, Pollution Degree 2. One
piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel
gasket and mounting clip included.
13. CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A
Safety requirements for electrical equipment for measurement, control,
and laboratory use:
EN 61010-1: General Requirements
RoHS Compliant
UL Listed: File #E179259 For Model No. PAXLA0U0 Only
Type 4X Enclosure rating (Face only)
IP65 Enclosure rating (Face only)
IP20 Enclosure rating (Rear of unit)
14. WEIGHT: 10.4 oz. (295 g)
1.0 InstallIng the Meter
Installation
The PAX meets NEMA 4X/IP65 requirements when properly installed.
The unit is intended to be mounted into an enclosed panel. Prepare the
panel cutout to the dimensions shown. Remove the panel latch from the
unit. Slide the panel gasket over the rear of the unit to the back of the
bezel. The unit should be installed fully assembled. Insert the unit into the
panel cutout.
While holding the unit in place, push the panel latch over the rear of
the unit so that the tabs of the panel latch engage in the slots on the
case. The panel latch should be engaged in the farthest forward slot
possible. To achieve a proper seal, tighten the latch screws evenly until
the unit is snug in the panel (Torque to approximately 7 in-lbs [79N-cm]).
Do not over-tighten the screws.
Installation Environment
The unit should be installed in a location that does not exceed the
maximum operating temperature and provides good air circulation.
Placing the unit near devices that generate excessive heat should be
avoided.
The bezel should be cleaned only with a soft cloth and neutral soap
product. Do NOT use solvents. Continuous exposure to direct sunlight
may accelerate the aging process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to
operate the keypad of the unit.
-.00
(92 )
-.0
+.8
3.62
+.03
(45 )
1.77
-.0
+.5
-.00
+.02
PANEL CUT-OUT
LATCHING
TABS
PANEL
LATCH
PANEL
MOUNTING
SCREWS
LATCHING
SLOTS
PANEL
GASKET
BEZEL