MODEL PAXH - AC TRUE RMS VOLT AND CURRENT
! FOUR VOLTAGE RANGES (300 VAC Max)
! FIVE CURRENT RANGES (5 A Max)
! ACCEPTS AC OR DC COUPLED INPUTS
! THREE WAY ISOLATION: POWER, INPUT AND OUTPUTS
MODEL PAXS - STRAIN GAGE INPUT
! LOAD CELL, PRESSURE AND TORQUE BRIDGE INPUTS
! DUAL RANGE INPUT: ±24 mV OR ±240 mV
! SELECTABLE 5 VDC OR 10 VDC BRIDGE EXCITATION
! PROGRAMMABLE AUTO-ZERO TRACKING
PAXS SPECIFICATIONS
SENSOR INPUTS:
PAXH SPECIFICATIONS
INPUT RANGES:
Isolation To Option Card Commons and User Input Commons: 125 Vrms
Isolation To AC Power Terminals: 250 Vrms
*Conditions for accuracy specification:
- 20 minutes warmup
- 18-28°C temperature range, 10-75% RH non-condensing
- 50 Hz - 400 Hz sine wave input
- 1% to 100% of range
- Add 0.1% reading + 20 counts error over 0-50°C range
- Add 0.2% reading + 10 counts error for crest factors up to 3, add 1% reading up to 5
- Add 0.5% reading + 10 counts of DC component
- Add 1% reading + 20 counts error over 20 Hz to 10 KHz range
** Non-repetitive surge rating: 15 A for 5 seconds
*** Inputs are direct coupled to the input divider and shunts. Input signals with
high DC component levels may reduce the usable range.
MAX CREST FACTOR (Vp/VRMS): 5 @ Full Scale Input
INPUT COUPLING: AC or AC and DC
INPUT CAPACITANCE: 10 pF
COMMON MODE VOLTAGE: 125 VAC working
COMMON MODE REJECTION: (DC to 60 Hz) 100 dB
INPUT
RANGE
ACCURACY*
MAX DC
BLOCKING
IMPEDANCE
(60 Hz)
MAX
CONTINUOUS
OVERLOAD
RESOLUTION
2 mA
0.1% of reading
+2 µA
±50 mA
111 ohm 50 mA
0.1 µA
20 mA
0.1% of reading
+20 µA
±150 mA
11.1 ohm 150 mA
1 µA
200 mA
0.1% of reading
+0.2 mA
±500 mA
1.1 ohm 500 mA
10 µA
5 A
0.5% of reading
+5 mA
±7 A***
0.02 ohm 7 A** 1 mA
200 mV
0.1% of reading
+0.4 mV
±10 V
686 Kohm 30 V 0.01 mV
2 V
0.1% of reading
+2 mV
±50 V
686 Kohm 30 V 0.1 mV
20 V
0.1% of reading
+20 mV
±300 V
686 Kohm 300 V 1 mV
300 V
0.2% of reading
+0.3 V
±300 V***
686 Kohm 300 V 0.1 V
200 µA
0.1% of reading
+0.4 µA
±15 mA
1.11 Kohm 15 mA
0.01 µA
CONNECTION TYPE: 4-wire bridge (differential)
2-wire (single-ended)
COMMON MODE RANGE (w.r.t. input common): 0 to +5 VDC
Rejection: 80 dB (DC to 120 Hz)
BRIDGE EXCITATION :
Jumper Selectable: 5 VDC @ 65 mA max., ±2%
10 VDC @ 125 mA max., ±2%
Temperature coefficient (ratio metric): 20 ppm/°C max.
INPUT RANGE
ACCURACY*
(18 to 28°C)
ACCURACY*
(0 to 50°C)
IMPEDANCE
MAX
CONTINUOUS
OVERLOAD
RESOLUTION
±24 mVDC
0.02% of
reading +3 µV
0.07% of
reading +4 µV
100 Mohm 30 V
1 µV
±240 mVDC
0.02% of
reading +30 µV
0.07% of
reading +40 µV
100 Mohm 30 V
10 µV
* After 20 minute warm-up. Accuracy is specified in two ways: Accuracy over an 18
to 28°C and 10 to 75% RH environment; and accuracy over a 0 to 50°C and 0 to
85% RH (non-condensing environment). Accuracy over the 0 to 50°C range
includes the temperature coefficient effect of the meter.