EasyManua.ls Logo

red lion RJS-100-PREM - User Manual

red lion RJS-100-PREM
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Table of Contents
Before Getting Started .................................................................2
Installation Checklist..................................................................... 3
Introduction ...................................................................................4
Voltage Setting Instructions ........................................................4
Materials and Tools Needed ......................................................... 5
Important Information ................................................................. 5
Quick Installation Guide ...............................................................6
Plug Descriptions and Socket Sizes ............................................. 6
Detailed Installation Instructions ................................................ 7
Typical Installations ......................................................................9
Pump to Tank Installation ...........................................................10
Wiring Instructions .......................................................................11
Priming the Pump .......................................................................12
Maintenance .................................................................................13
Troubleshooting ........................................................................... 14
Replacement Parts ......................................................................15
Limited Warranty ......................................................................... 16
ENGLISHEN
PREMIUM SHALLOW
WELL JET PUMP
RJS-PREM Series
Owner’s Manual
THIS PUMP IS DUAL VOLTAGE AND FACTORY SET FOR 230 VOLTS.
SEE VOLTAGE SETTING INSTRUCTIONS TO SET FOR 115 VOLTS.
redlionproducts.com

Questions and Answers

  • J
    James ClineAug 7, 2025
    Why does my Red Lion Water Pump lose prime?
    • D
      Diana BushAug 7, 2025
      Your Red Lion Water Pump might be losing prime because of air leaks in the suction line; inspect the suction line for these leaks. Another cause could be the well drawing down too far, so monitor the well draw down. A faulty foot valve could also be the reason; consider replacing it.
  • P
    Peter NealAug 12, 2025
    What to do if red lion RJS-100-PREM Water Pump is losing pressure or unable to prime in well point installations?
    • D
      dbergAug 13, 2025
      For well point installations where the Red Lion Water Pump is losing pressure or is unable to prime, have an electrician install a low pressure cut-off switch to shut down the pump prior to critical failure. Install or adjust a restrictor valve to offset available capacity. Add a larger tank (20 gallon or larger) for additional capacity.
  • C
    Cynthia RobertsonAug 17, 2025
    Why does my Red Lion Water Pump start and stop too often?
    • D
      Dana SullivanAug 17, 2025
      Your Red Lion Water Pump might be starting and stopping too often due to several reasons. It could be a faulty air volume control, which needs replacement or repair. Air leaks in the tank above the water level could also be the cause, so check for those. The pressure switch might be incorrectly set, requiring adjustment. The tank could also be waterlogged or incorrectly charged, necessitating a recharge or assessment. Finally, a leaking or stuck-open foot valve could be the culprit, requiring inspection and repair.
  • V
    Vanessa GrossAug 22, 2025
    What to do if my red lion RJS-100-PREM delivers water but not at rated capacity?
    • M
      Miss Monica Sanders MDAug 22, 2025
      If your Red Lion Water Pump isn't delivering water at its rated capacity, several factors could be responsible. Check for leaks in the suction or discharge line and repair them. The foot valve, suction line, impeller, or nozzle might be partially plugged, so clear any blockages. Ensure the suction lift meets recommended levels. Verify the impeller rotation and speed are correct. Also, check if the venturi or diffuser is plugged and unplug it if necessary. Confirm the motor is wired for the proper voltage and that the line voltage at the motor is correct. Lastly, if a filtration cartridge is used, ensure it's correctly installed or needs changing.
  • V
    Vincent RussellAug 27, 2025
    How to fix a red lion RJS-100-PREM motor that will not start?
    • A
      Andrew RodriguezAug 27, 2025
      If your Red Lion Water Pump motor isn't starting, it could be due to a few reasons. First, check for blown fuses, open switches, or loose connections preventing power from reaching the pressure switch; replace any blown fuses, ensure switches are closed, and tighten connections. Another possibility is that the pump pressure switch isn't closed, so verify its position.
  • M
    melindastoneSep 1, 2025
    What to do if my Red Lion Water Pump fails to deliver water?
    • T
      Traci WilkinsSep 1, 2025
      If your Red Lion Water Pump isn't delivering water, make sure the pump is completely primed. Also, the suction lift might be too great, and you may need to reduce it. Check that the foot valve is submerged, not buried in mud, and not plugged. Finally, make sure the restrictor valve is open.

Summary

Before Getting Started

Electrical Precautions

Ensure all wiring and connections comply with electrical codes and ordinances.

Risk of Electric Shock

Safety measures to prevent electric shock, including proper wiring and grounding.

Voltage Setting Instructions

Voltage Change Device Operation

Instructions and diagrams for changing the pump's voltage setting.

Important Information

Suction and Pressure Pipe

Recommendations for suction and discharge pipes, including material, slope, and airtight connections.

Quick Installation Guide

Detailed Installation Instructions

Pump to Tank Installation

Wiring Instructions

Electrical Connections and Wire Sizing

Guidance on wiring the pump, including electrical precautions, connections, and wire length recommendations.

Priming the Pump

Maintenance

Troubleshooting

Replacement Parts

red lion RJS-100-PREM Specifications

General IconGeneral
Horsepower1 HP
Voltage115/230V
Pump TypeJet Pump
MaterialCast Iron
PhaseSingle Phase