Page | 8 Ascento 37 Export St Lytton QLD PH: 1800 807 604 | VSRM Inverter Contant Pressure Pumps | V2016.12
Starts the pump manually, also resets the Inverter when it is
in the “Failure” mode, back to normal running.
However if there is a water shortage, it will revert to Failure
again
4. Maintenance
4.1 MONTHLY: The Owner/User must check the Y-Strainer or Pre-filter monthly and clean/flush it to ensure there is
no restriction on the suction of the water from the tank. Also clean dust, dirt, leaves and cobwebs etc off the pump,
and ensure there is no restriction to the airflow around the pump. Check for leaking pipework, taps & toilets, leaks
cost you money!!
4.2 Repairs to the pump need to conducted by qualified persons, and only genuine parts fitted. If a reduction in
pressure is noticed, it could indicate debris is in the pump, check the settings, check water supply from the tank. If
no cause found, a competent person should open the pump (wet-end) and clean the impellers and diffusers.
4.3 No other regular maintenance should be necessary.
4.4 If the pump is starting frequently or not stopping, it nearly always means something is leaking. This is wasting
water, power and your money!! To easily check if it is a leak, ensure no-one is using the water, then turn the pump
off at the power. Watch the pressure gauge, if it is slowly going down (pressure in the pipes is reducing) this tells
you that something is leaking. Carefully and thoroughly check all outlets, turn off toilet cisterns as they are common
problem. If it is certain that it is not outlets, check the backflow valve (check valve) it might have debris in it and the
water is escaping backwards. The pump will run on continuously due to any minor leaks/or you have drip
irrigation/or very slow use. Also check the pressure setting (if it is too high it will not stop) or if it is leaks or drip
irrigation that you cannot stop, you MUST install an additional larger PRESSURE TANK between the pump and the
first point of discharge, to avoid the continuous running. We suggest a REEFE Pressure Tank PT35H or larger.
Warranty is voided by continuous running of the pump.
4.5 If the pump will not be used for a long time, disconnect the power and drain the pump. If it is not used for 18
months or more the capacitors must be replaced by a Licenced Electrician.
5. TROUBLESHOOTING
Check the following before requesting service or repair. A call out fee and labour cost may apply to field services.
Fault Codes;
When the voltage is higher than 270V it shows this code, once the
Voltage reduces back to less than 260V, VSRM will revert to normal
operation.
If the voltage is lower than 100V it shows this code, once the
Voltage increases back above 110V, VSRM will revert to normal
operation.
When the VSRM air-cooled radiator temperature reaches 80℃ it
shows this code, when the temperature drops back to lower than
60℃, the VSRM will revert to normal operation.
Sensor error
(Transducer)
If the Transducer (Pressure Sensor) is damaged or disconnected
this code displays, the VSD will revert to normal operation after
the problem is rectified/the Transducer is replaced.