SP 1, SP 2, SP 2.3, SP 2.4 9
SPR1, SPR 2, SPR 2.3, SPR 2.4
Electric motor
1)
Nominal
Type
Number
Operating
time
±
10[%]
Operating angle
Switching-
off torque
±10 [%]
Weight
Power supply
nominal voltage
power
speed current
Capacitor
capacity
[s/90°]
[°] [Nm] [kg] [V] [W] [1/min] [A] [μF/V]
1 2 3 6 7 8 9 10 11 12 13
5 72
10
20
60
2750 0,70 7/400
40
80
145
Single-phase
220/
230
20 1350 0,50 7/400
5 72
10
20
40
145
Single-phase/
direct current-
voltage
24 AC/
DC
65 2800 5,00 -
5 72
10
20
SP 2/SPR 2
Type Nr. 282
40
145
11,5 – 16,5
Three-phase
3x380/
3x400
90 2740 0,35 -
20
40
60 2750 0,70
80
160
290
220/
230
20 1350 0,50
7/400
Single-phase
20
40
80
290
24 AC/
DC
65 2800 5,00 -
Single-phase/
direct current-
voltage
20
40
80
290
3x380/
3x400
90 2740 0,35 -
SP 2.3/SPR 2.3
Type Nr. 283
17,0 – 35,0
Three-phase
40
80
60 2750 0,70 7/400
160
575
20 1350 0,50 7/400
Single-phase
220/
230
40
80
575 65 2800 5,00 -
24 AC/
DC
Single-phase/
direct current-
voltage
40
80
575 90 2740 0,35 -
SP 2.4/SPR 2.4
Type Nr. 284
60°, 90°, 120°, 160°, without stop ends 360°,
without stop ends and without transmitter >0°, <360°
20,5 – 55,5
Three-phase
3x380/
3x400
1) Switching elements for different type of load (also for EA) defines standard EN (IEC) 60 947-4-1.