GALVANIC/STRAY CURRENT CORROSION
Cause/Observed Condition Corrective Action
Sacricial anodes consumed Replace anodes when 30%
consumed
Sacricial anodes not grounded
to drive
Remove anodes, clean contact
surface, reinstall, check for
continuity
Loss of continuity between
underwater parts & ground
Provide good ground connec-
tions
Nearby vessel with stray current Contact appropriate personnel
Remove your vessel from water
Paint on drive heavily worn,
exposing more metal
Prime and repaint or install ad-
ditional anodes
Sacricial anodes painted Remove paint or replace anodes
Drive tilted/anodes out of
water
Leave drive down, install addi-
tional anodes below water
Power trim cylinders only cor-
roded
Provide a good ground to drive,
all parts must be grounded
Corrosion in area of exhaust
outlets
Remove deposits
Corrosion occuring after vessel
is removed from saltwater
Wash exterior and ush interior
with freshwater
Stainless steel parts corroding Clean parts, remove foreign
material, ensure continuity
Underwater drive parts corrod-
ed, sacricial anodes OK
Oxide lm on anode (fresh wa-
ter only) Replace anode
Poor grd. Remove/scrape anode