EasyManua.ls Logo

REMEHA Sol Plus - Page 39

REMEHA Sol Plus
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en
39
InstallationIndications, functions and optionsMessages Commissioning Operation and function
PUM2
Pump control type R2
Selection: OnOF, PULS, PSOL, PHEA
Factory setting: OnOF
With this parameter, the pump control type can be adjusted. The following types
can be selected:
Adjustment for standard pump without speed control
OnOF (pump on / pump off)
Adjustment for standard pump with speed control
PULS (burst control via semiconductor relay)
Adjustment for high-efciency pump (HE pump)
PSOL (PWM prole for a HE solar pump)
PHEA (PWM prole for a HE heating pump)
Minimum speed
n2MN
Minimum speed R2
Adjustment range: (10) 30 100
Factory setting: 30
A relative minimum pump speed can be allocated to the output R2 via the adjust-
ment channel n2MN.
Note
The pump speed must be set to 100 % when auxiliary relays or valves are
connected.
Maximum speed
n2MX
Maximum speed R2
Adjustment range: (10) 30 … 100 %
Factory setting: 100 %
In the adjustment channel n2MX a relative minimum speed for a pump connected
can be allocated to the output R2.
Note
The pump speed must be set to 100 % when auxiliary relays or valves are
connected.