2 Technical data
2.1 Unit data
Series Easy-Control EC1
Power supply V/Hz 230 AC, 50
Current load (heating cycle pump) A 3
Probe NTC3950, l0K
Accuracy °C/F ± 0.5/± 1
Set the temperature °C 5-35
Temperature display °C 5-99
Ambient temperature °C 0-45
Humidity (non-condensing) % rel. hum. 5-95
Storage temperature °C 5-45
Current consumption W < 1.5
Timing error % < 1
Housing PC +ABS (fire-resistant)
Suitable flush-mounted socket mm
86 x 86 square or European 60 mm
round box
Wire clips
mm
2
Wire 2 x 1.5 or 1 x 2.5
Enclosure class IP30
Keys Capacitive touch keys
We reserve the right to make technical changes for the purpose of technical advancement.
2.2
Unit dimensions
60 (±2)
86
86
50
14
14
24
50
90
50
90
A
B
C
Fig. 1: Dimensions (all measurements in mm)
A: Front view
B: Side view
C: Rear view
7