32
REMKO GPM
Country Category Natural gas Pressure Liquid gas Pressure
AT
II
2H3B/P
G20 20 mbar G30/G31 50 mbar
BE <70 kW
I
2E(S)B,I3P
G20/G25 20/25 mbar G31 37 mbar
BE >70 kW
I
2E(R)B,I3P
G20/G25 20/25 mbar G31 37 mbar
CH
II
2H3B/P
G20 20 mbar G30/G31 50 mbar
DE
II
2ELL3B/P
G20/G25 20 mbar G30/G31
50 mbar
DK, FI, GR, SE
II
2H3B/P
G20 20 mbar G30/G31 30 mbar
ES, GB, IE, PT
II
2H3P
G20 20 mbar G31
37 mbar
IT
II
2H3B/P
G20 20 mbar G30/G31 30 mbar
FR
II
2Esi3P
G20/G25 20/25 mbar G31 37 mbar
LU
II
2E3P
G20/G25 20 mbar G31 37/50 mbar
NL
II
2L3B/P
G25 25 mbar G30/G31 30 mbar
NO, HR
II
2H3B/P
G20 20 mbar G30/G31 30 mbar
HU
II
2HS3B/P
G20/G25.1 25 mbar G30/G31 30 mbar
CZ
II
2H3B/P
G20 20 mbar G30/G31
30 mbar
CY, MT
I
3B/P
G30/G31 30 mbar
EE, LT, LV
II
2H3B/P
G20 20 mbar G30/G31 30 mbar
IS
I
3P
G31 37 mbar
SK
II
2H3B/P
G20 20 mbar G30/G31 30 mbar
SI
II
2H3B/P
G20 20 mbar G30/G31 30 mbar
BG, RO, TR
II
2H3B/P
G20 20 mbar G30/G31 30 mbar
PL
II
2ELwLs3B/P
G20/G2,350 20/13 mbar G30/G31 37 mbar
Country table of gas types
Gas type G20 G25 G30 G31
Category according to country of destination (see table above)
Supply pressure (mbar)
20
(min.17-max.20)
25
(min.20-max.30)
30 - 50 30 -50
Ignition gas nozzle Ø (mm) 0.60 0.60 (0.65) 0.51 0.51
Carbon dioxide CO
2
(%)
8.7 ±0.2 (cat.H)
8.9 ±0.2 (cat.E)
8.7 ±0.2 9.6 ±0.2 9.4 ±0.2
Gas burner adjustment values / flue gas analysis
The initial commissioning may only be conducted by authorised technicians.
The initial commissioning also comprises the combustion analysis, which is mandatory.
The units are permitted in EC countries and outside of the EC for the following types of gas listed below.