ZXT-800 AC/AV MASTER USER MANUAL
Parameter Name/
Description
Parameter
Number
Parameter Value Size (Byte)
Learn AC IR code 25 (0x19)
Storage location 0 –32 for AC IR code
learning (refer to AC learning mapping
table)
1
Learn AV IR code 26 (0x1A)
Storage location 0 –40 for AV IR code
learning (refer to AV learning mapping
table)
1
Set IR code from
built-in AC library
27 (0x1B)
Refer to AC code list nd from code
nder page by code list QR code AC
Learning code number = 0000(0x0000)
2
External IR Emitter
power level
28 (0x1C)
0(0x00) - normal power mode
255(0xFF) - high power mode (default)
1
Set Auto Report
Condition, Trigger
by Room
Temperature
change
30 (0x1E)
0(0x00) = Disable AUTO report
function (default) It can extend
the battery life.
Auto report if room temperature is
different from last report
1(0x01) = 1°F (0.5°C)
2(0x02) = 2°F (1°C)
3(0x03) = 3°F (1.5°C)
4(0x04) = 4°F (2°C)
5(0x05) = 5°F (2.5°C)
6(0x06) = 6°F (3°C)
7(0x07) = 7°F (3.5°C)
8(0x08) = 8°F (4°C)
1
Set Built-in IR
Emitter Control
32 (0x20)
It is allowed to disable internal
IR emitter if use external IR emitter
jack, it can extend the battery life.
0(0x00) = Disable
255(0xFF) = Enable (default)
1