ZXT-800 AC/AV MASTER USER MANUAL
Select AV endpoint 38 (0x26)
2(0x02) = end point 2 (AV1) default
3(0x03) = end point 3 (AV2)
4(0x04) = end point 4 (AV3)
1
Calibrate humidity
reading
53 (0x35)
0(0x00) = 0% (default)
1(0x01) = 1% to 30(0x1E) = 30%
255(0xFF) = -1% to 226(0xE2) = -30%
1
Trigger BLE
advertising
60 (0x3C)
0(0x00) = Disable BLE advertising
(default)
255(0xFF) = Enable BLE advertising,
please also set Parameter 61 below.
(If the ZXT-800 is installed at ceiling
location, user can trigger BLE
advertisement through the Z-Wave
Conguration without click the
PROG button.)
1
BLE advertising
option
61 (0x3D)
0(0x00) = ZXT-800 advertises for 10
minutes then stop (default)
1(0x01) = ZXT-800 keep advertising,
it is suitable for USB supply power
1
Device reset to
default
160 (0xA0) 255(0xFF): device reset to default 1
5. Reset to Factory Default
• Press and keep holding “PROG” button not less than 10 seconds.
• LED will light up at rst 5 seconds, LED ashes twice then stay off after reset process
completed.
• Device will be excluded from network, All Conguration Parameters will be restored to
factory default. All downloaded IR data and learned data will be cleared.
• ZXT-800 will send Device Reset Locally Notication to gateway.
• ZXT-800 will not implement the Reset to Factory Default when the battery level below
20%.
CONTENTS [ 18 | 23 ]