ZXT-800 AC/AV MASTER USER MANUAL
Control Air
conditioner “Swing”
function
33 (0x21)
0(0x00) = Swing OFF
1(0x01) = Swing Auto (default)
1
Temperature and
Humidity Auto
Report
34 (0x22)
Set Auto Report Condition by Time
Interval
0(0x00) = Disable AUTO report
(default)
1(0x01) = 15 mins
2(0x02) = 30 mins
3(0x03) = 1 Hr
4(0x04) = 2 Hrs
5(0x05) = 3 Hrs
6(0x06) = 4 Hrs
1
Calibrate
temperature
reading
37 (0x25)
Temperature offset value
0(0x00) = 0°C (default)
1(0x01) =0.5°C
2(0x02) = 1°C
3(0x03) = 1.5°C
4(0x04) = 2°C
5(0x05) = 2.5°C
6(0x06) =3°C
7(0x07) = 3.5°C
8(0x08) = 4°C
9(0x09) = 4.5°C
10(0x0A) = 5°C
255(0xFF) = -0.5°C
254(0xFE) = -1°C
253(0xFD) = -1.5°C
252(0xFC) = -2°C
251(0xFB) = -2.5°C
250(0xFA) = -3°C
249(0xF9) = -3.5°C
248(0xF8) = -4°C
247(0xF7) = -4.5°C
246(0xF6) = -5°C
1
CONTENTS [ 17 | 23 ]