1. Technical Data
The REMS CamScope and REMS CamScope S endoscope camera is used for the inspection and damage analysis of locations with difcult access such as cavities,
shafts, pipes etc. and serves for documenting the inspection results in the form of photos and videos, in the REMS CamScope S in the form of videos with voice
recording. The camera cable sets of REMS CamScope and REMS CamScope S are protected against temporary immersion in water (≤ 30 min, ≤ 0.1 bar).
1.1. Supply Format Set 16-1 Set 9-1 Set 4.5-1
REMS CamScope 175110 175111 175112
* Supply format * Supply format * Supply format
Camera cable set Color 16-1 Camera cable set Color 9-1 Camera cable set Color 4.5-1
Add-on mirror, add-on hook Add-on mirror, add-on hook
Add-on magnet Add-on magnet
REMS CamScope S 175130 175131 175132
* Supply format * Supply format * Supply format
Camera cable set Color 16-1 Camera cable set Color 9-1 Camera cable set Color 4.5-1
Add-on mirror, add-on hook Add-on mirror, add-on hook
Add-on magnet Add-on magnet
* Supply format:
Handheld unit, 4 batteries 1.5V, AA, LR6, controller unit, MicroSD-card 2 GB, power supply/charger unit, USB-cable, video cable, case
1.2. Accessories
Camera cable set Color 16-1 175103
Camera cable set Color 9-1 175104
Camera cable set Color 4.5-1 175102
900 mm push cable extension 175105
1.3. Handheld Unit REMS CamScope REMS CamScope S
Transmission frequency 2,468 MHz 2,468 MHz
Modulation type FM FM
Bandwidth 18 MHz 18 MHz
Radio transmission range up to 10 m up to 10 m
Power supply 4 batteries 1.5 V, AA, LR6 4 batteries 1.5 V, AA, LR6
Dimensions 190 × 140 × 40 mm 190 × 165 × 53 mm
Weight 260 g 320 g
1.4. Controller Unit REMS CamScope REMS CamScope S
Display 3.5” Color TFT-LCD 3.5” Color TFT-LCD
Pixels (display) 320 × 240 320 × 240
Pixels (recording) 640 × 480 640 × 480
Video system PAL / NTSC PAL / NTSC
Reception frequencies 2414, 2432, 2450, 2468 MHz 2414, 2432, 2450, 2468 MHz
Transmission channel 4 not adjustable
Rechargeable batteries integrated Li-Ion battery 3.7 V, 1.2 Ah integrated Li-Ion battery 3.7 V, 1.2 Ah
Power supply / charger unit 100 – 240 V AC, 50 – 60 Hz, Input / 100 – 240 V AC, 50 – 60 Hz, Input /
5 V DC, 1 A, Output DC 5 V / 1 A, Output
Video level 0.9 – 1.3 Vpp on 75 Ohm 0.9 – 1.3 Vpp on 75 Ohm
Video rate 27 MB per minute 27 MB per minute
Frame rate up to 30 frames per second up to 30 frames per second
Zoom 1.5 / 2.0 / 3.0 ×
Dimensions 100 × 70 × 25 mm 105 × 90 × 42 mm
Weight 130 g 240 g
Temperature range –10°C ... +50°C / +14°F ... +122°F –10°C ... +50°C / +14°F – +122°F
Humidity 15 – 85% RH 15 – 85% RH
1.5. Camera Cable Set Color 16 mm camera 9 mm camera 4.5 mm camera
Image sensor CMOS CMOS CMOS
Number of pixels 704 × 576 640 × 480 320 × 240
Viewing angle 50° 36° 63°
Focus range 60 – 350 mm 20 – 100 mm 10 – 50 mm
Min. lighting 0 lux 0 lux 0 lux
Power supply by handheld unit by handheld unit by handheld unit
Dimensions Ø 16 × 970 mm Ø 9 × 970 mm Ø 4.5 × 1030 mm
Weight 280 g 190 g 30 g
Video format PAL PAL NTSC
Type of protection camera IP 67 IP 67 IP 67
2. Start-up
Remove the screw from the battery compartment (17) of the handheld unit (5)
(only in REMS CamScope), push the cover in the direction of the arrow to
remove, remove the battery holder, insert 4 1.5 V, AA, LR6 batteries into the
battery holder, pay attention to the position of the plus-minus poles. Push the
battery holder back into the battery compartment, slide in the cover, screw in
the screw (only in REMS CamScope). Always change all four batteries at once.
The controller unit has an integrated Li-Ion battery. Caution: Mains voltage
present! Charge the controller battery before start-up. To do so, connect the
supply voltage/Li-Ion charger to the charger/mains socket (16) of the controller
unit and a suitable wall socket. The battery charging time is approximately 3
hours. A full charge lasts for about 2 hours of operation depending on the use.
The controller unit can also be operated with the connected supply voltage/
charger.
Push the controller unit (7) onto the handheld unit (5) from above until it snaps
into place. When inserting the camera cable set (2), make sure that the pin on
the cable plug (3) is pushed into the slit in the cable socket on the handheld
unit (5). Tighten the knurled nut.
The controller unit can be operated both by radio signal and directly with the
handheld unit. If the controller unit (7) is xed to the handheld unit (5), the signal
transmission takes place via the contact pins on the controller unit and on the
handheld unit. Transmission switches over to radio signal transmission as soon
as the controller unit is removed from the handheld unit. For radio-controlled
operation, make sure that the controller of the REMS CamScope is set to channel
CH 4. This is indicated in the top left hand corner of the display. If this setting
should deviate, it can be corrected to CH 4 by pressing the Down button (12)
several times. No channel must be set manually in the REMS CamScope S.
WMV-Dresden, Ersatzteilservice für Elektrowerkzeuge, Motor- und Gartengeräte

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REMS CamScope and is the answer not in the manual?

REMS CamScope Specifications

General IconGeneral
BrandREMS
ModelCamScope
CategoryAnalytical Instruments
LanguageEnglish

Related product manuals