Wet Trimming:
Fault Possible cause Corrective action
Disc buildup. Water volume incorrectly ad-
justed at the device�
Water supply not fully open�
Spray tube plugged�
Inlet strainer plugged�
Inlet water pressure too low
Increase the water volume at the trimmer
(Fig� 9)�
Open the water supply (Fig� 6)�
Clean / decalcify the spray tube (Sec� 8�3)�
Remove the strainer with pliers and clean /
decalcify it�
The diameter of the inlet pipe is too small
risp� too many users are connected to a
small pipe >>> Check if water pressure is
at least 1 bar (ask your plumber)� If neces-
sarythewaterpressurecanarticiallyin-
creased by a domestic water work (electric
pump and pressure tank)�
Ask your plumber
Water sprays out
of the grinding
opening.
Too much water
Water drainage impeded�
Reduce the water volume at the trimmer
(Fig� 9)�
Check/properly lay out drain tube >>>
slope(Fig.3a+3b).
No rinse water. Water connection not properly
established�
Spraytubesoiled/calcied.
Check the water connection (Sec� 7�2 steps
4 - 6)�
Clean/decalcify the spray tube (Sec� 8�3)�
Water is dripping
out between the
front door and the
housing.
Gipsum powder order plaster
grains on the sealing surface�
Clean the sealing surface and the sealing
ring�
Dry Trimming:
Fault Possible cause Corrective action
Disc buildup. Models are too wet� Clean the disc with a brush under running
water or with plaster solvent
(Renfert GO-2011 Art� No� 2011-0000)�
Excessive dust
being blown out
of the grinding
opening.
Extraction not switched on�
Insufcientsuction.
Extractor or dust bag full�
Extractor hose blocked�
Switch the extraction on�
Increase the suction�
Replace the dust bag�
Check / clean the hose�