HOME 27
How do I verify that the Lithium Battery is charging?
• On the Samkoon Screen:
o Review the Top Bubble which states Charge or
Discharge.
o Review the Total Current - Negative Current means the
system is discharging and positive current means charging.
Alternator: Depending on total voltage and other circumstances, the typical total
current can range from 0-100A.
Shore Cord: Depending on total voltage and other circumstances, the typical total
current can range from 0-40A.
Solar Power: Depending on total voltage and other circumstances, the typical total
current can range from 0-4A.
• On the Inverter Screen, review to ensure that the inverter is showing the solar and/or utility charging:
If my Lithium Battery has a fault, what do I need to do?
Refer to the BMS Warnings & Protections chart in the 51.2V 210Ah Lithium Battery section (above) for the
triggering and recovery condition of each warning and protection.
• Most common faults are Battery Under-Voltage, Battery Cell Over-Voltage and Charge Low
Temperature.
o Battery Under-Voltage or Cell Under-Voltage: plug in the shore cord to charge the
lithium battery to the recovery condition.
o B
attery Over-Voltage or Cell Over-Voltage: remove any charging sources and utilize
the 12V or 48V system to draw down the battery to the recovery condition.
o C
harge Low Temperature: Bring the unit inside to allow the unit to warm or warm the
unit with the internal heaters by connecting the shore power, it will provide a stable charge
current greater than 8A required for the self-heating function to operate normally.
• NOTE: Warnings will automatically disappear and Protections will require restarting the Lithium
Battery.
How do I verify my shore power is charging on the inverter?
Orange light will flash while
inverting.
Orange light will be solid when
shore power is connected.
during a fault with a
Green light will flash while charging.