If output ports can be turned
on, it means that the loads
drew too much power from
the unit and pulled down the
battery voltage. In this case,
only connect small loads to
the unit.
3.
4.
All Battery Level LED Indicators
and the Ports Status LED
Indicator of USB-A Ports flash
twice per second
USB-A Ports Overcurrent
2.6A)
USB-A Ports Short-circuit
Protection
1.
2.
Remove connections to the
USB-A Ports
1.
All Battery Level LED Indicators
and the Ports Status LED
Indicator of DC Output Port and
CIG Port flash twice per second
DC Output Port Overcurrent
6.5A)
1.
CIG Port Overcurrent
12.1A)
2.
DC Output Port Short-circuit
Protection
3.
Remove connections to the
DC Output Port and CIG Port.
1.
If the USB-A Ports were shorted,
remove the short circuit
immediately.
If none of the output ports can
be turned on, it means that the
unit should not continue
powering loads. In this case,
recharge the unit as soon as
possible to avoid permanent
damages to the battery.
2.
If the loads drew currents that
exceed the specifications of
USB-A Ports, stop powering
those loads via the USB-A
Ports.
3.
4.
Press the Port On/Off Button
to turn on the USB-A Ports
again and connect only the
loads that conform to the
specifications of USB-A Ports
to the unit.
If the DC Output Port or CIG
Port was shorted, remove the
short circuit immediately.
2.
If the loads drew currents that
exceed the specifications of DC
Output Port or CIG Port, stop
3.
- 14 -