EasyManuals Logo

REO REOVIB MFS 268 User Manual

REO REOVIB MFS 268
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
REOVIB MFS 268
Operating Instructions EtherNet/IP - Programming
11
Parameter:
Adjustment Display-
Code
Factory
Setting:
Entry
code
Parameter
address
HEX (.bit)
Value
HEX
Service limits
Enable service menu
0 / I En.S. 0 127 0x5834
0x0000 / 0x FFFF
Show output current (0... 100 %)
i. 040 0x200A
0x0000...0x8000 H
Show active vibration frequency
F. 040 0x1005
0x01F4...0x7530 H
Current limit
0...100 % I. 100 040 0x1016
0x0000...0x8000 H
Stop at current limit
0 / I E.F.u. 0 040 0x5850
0x0000 / 0x FFFF
Current regulator P-part
1…100 I.P. 20 040 0x100D
0x0000...0xFFFF
Current regulator I-part
1…100 I.I 40 040 0x1032
0x0000...0xFFFF
Min frequency limit
5...150 Hz
F.L: 35 040 0x1020
01F4...7530 H
500...30000 dec.
Max frequency limit
5...150 Hz
F.H. 140 040 0x1021
01F4...7530 H
500...30000 dec.
Start level AFC
0…100 A.S. 25 040 0x1033
0x0000...0xFFFF
Output voltage limited
0…100 P.L. 100 040 0x1018
0x0000...0xFFFF
1) Not available IP20 Version
2) Not for fieldbus operation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REO REOVIB MFS 268 and is the answer not in the manual?

REO REOVIB MFS 268 Specifications

General IconGeneral
BrandREO
ModelREOVIB MFS 268
CategoryIndustrial Electrical
LanguageEnglish

Related product manuals