EasyManua.ls Logo

REO REOVIB MFS 268 - Communication Examples and Controller Reset

REO REOVIB MFS 268
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REOVIB MFS 268
Operating Instructions EtherNet/IP - Programming
12
7.0 Example of bus communication with Frequency controller
Variable values are shown in italics.
7.1 Normal mode
(Set point to 70 %)
Send Set
point
Word Code
send
Code
Received
1 0000 H
0000 H
2 B332 H
Set point = 70 %
--- ---
3
4
0004 H
Enable On
A5xx H
Ready
Enable ON, Stop controller (with enable)
Send Set
point
Word Code
send
Code
Received
1 0000 H
0000 H
2 B332 H
Set point = 70 %
--- ---
3
4
0000 H
Enable OFF
A5xx H
Ready
7.2 Parameter mode
(e.g. set frequency to 50 Hz and soft start to 2 second)
Open write
enable
Word Code
send
Code
Received
1 0000 H
0000 H
2 C0DE H Write enable Address C0DE H Acknowledge
3 B5E7 H Write enable value B5E7 H Acknowledge
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge
Write param
eter
1 0000 H
0000 H
2
9005 H
Parameter address
Vibrating frequency
+ R / W - Bit
9005 H
Acknowledge
3
1388H
Frequency 50 Hz
1388 H
Acknowledge 50 Hz
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge
Write param
eter
1 0000 H
0000 H
2
9013 H
Parameter address
Soft start
+ R / W - Bit
9013 H
Acknowledge
3
3333 H
Soft start 2 Sec.
3333 H
Acknowledge 2 seconds
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge
Close Write
enable
Word Code
send
Code
Received
1 0000 H
0000 H
2 C0DE H Write enable address C0DE H Acknowledge
3 0000 H Write enable Value 0000 H Acknowledge
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge

Related product manuals