REOVIB MFS 268
Operating Instructions EtherNet/IP - Programming
12
7.0 Example of bus communication with Frequency controller
Variable values are shown in italics.
7.1 Normal mode
(Set point to 70 %)
Send Set
point
Word Code
--- ---
3
4
0004 H
Enable On
A5xx H
Ready
Enable ON, Stop controller (with enable)
Send Set
point
Word Code
--- ---
3
4
0000 H
Enable OFF
A5xx H
Ready
7.2 Parameter mode
(e.g. set frequency to 50 Hz and soft start to 2 second)
2 C0DE H Write enable Address C0DE H Acknowledge
3 B5E7 H Write enable value B5E7 H Acknowledge
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge
2
9005 H
Parameter address
Vibrating frequency
+ R / W - Bit
9005 H
Acknowledge
3
1388H
1388 H
Acknowledge 50 Hz
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge
2
9013 H
Parameter address
Soft start
+ R / W - Bit
9013 H
Acknowledge
3
3333 H
3333 H
Acknowledge 2 seconds
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge
2 C0DE H Write enable address C0DE H Acknowledge
3 0000 H Write enable Value 0000 H Acknowledge
4 8000 H +
Control bits
Set mode bit = 1 C0DE H Acknowledge