EasyManuals Logo

REO REOVIB MFS 268 User Manual

REO REOVIB MFS 268
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
REOVIB MFS 268
Operating Instructions EtherNet/IP - Programming
9
5.2.5 Close write enable
H-Byte L-Byte
Wort
0000 H
0
0
0
0
H-Byte L-Byte
Word
2
Write Enable Address = C0DE H
C0
DE
H-Byte L-Byte
Word
3
Enable Value 0000
00 00
H-Byte L-Byte
Word
4
Control - Word + 8000 H
Mode bit must be set to `1`!
All unused bits must be set to `0`
Bit = `1` = Function ON
15
14 13 12
11 10 9 8 7 6 5 4 3 2 1 0
1 Mode bit
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Control Information (unit specific)
5.2.6 Parameter read (send)
H-Byte L-Byte
Wort
xxxx H (undefined)
0
0
0
0
H-Byte L-Byte
Word
2
Parameter address + R / W - Bit
15
14 13 12
11 10 9 8 7 6 5 4 3 2 1 0
R / W
Parameter address
H-Byte L-Byte
Word
3
Read Enable Value = 0000
00
00
H-Byte L-Byte
Word
4
Mode bit = 1 + Control bits
80
00
Received parameter
H-Byte L-Byte
Wor
1
xxxx H (undefined)
0
0
0
0
H-Byte L-Byte
Word
2
Acknowledge
Parameter address + R / W - Bit
15
14 13 12
11 10 9 8 7 6 5 4 3 2 1 0
R / W
Parameter address
H-Byte L-Byte
Word
3
Parameter value
XX
XX
H-Byte L-Byte
Word
4
Ackowledge Parameter mode
C0
DE