Device Type | CPAP Machine |
---|---|
Modes | CPAP, AutoSet, AutoSet for Her |
Humidification | Integrated HumidAir humidifier |
Display | Color LCD touch screen |
Pressure Range | 4-20 cm H2O |
Water Chamber Capacity | 380 mL |
Altitude Adjustment | Automatic |
Connectivity | Bluetooth, Cellular |
Weight | 1.13 kg (2.49 lbs) (device with water tub) |
Heated Tubing Option | ClimateLineAir |
Data Storage | SD Card |
Power Supply | AC 100-240V, 50-60Hz |
Operating Conditions | 5°C to 35°C (41°F to 95°F) |
Compatibility | ResMed masks |
Ramp Time | 0-45 minutes (AutoRamp available) |
Dimensions | 259 x 129 x 150 mm (10.2 x 5.1 x 5.9 inches) |
Describes the intended use for treating obstructive sleep apnea (OSA).
Lists conditions where positive airway pressure therapy may be contraindicated.
Lists potential side effects experienced during therapy.
Grants a limited license for using the ResMed Software with the device.
Explains automatic download of software updates via cloud connectivity.
Details how device data is used for therapy benefits, surveillance, and research.
Explains how the device adjusts pressure based on breath-by-breath analysis.
Describes the typical flow-time curve for a normal breathing pattern.
Explains how flow limitation affects the inspiratory flow-time curve.
Defines snoring as vibrations of upper airway walls.
Explains how the device detects and responds to obstructive and central apneas.
Details therapeutic responses tailored for female OSA patients.
Explains CPAP mode delivers fixed pressure with optional Expiratory Pressure Relief.
Explains CSA detection using Forced Oscillation Technique (FOT).
Describes Cheyne-Stokes respiration (CSR) and its characteristics.
Explains RERA reporting and how it's logged and stored.
Details the ramp feature for comfortable pressure increase at the start of therapy.
Explains EPR for comfortable exhalation and reduced pressure.
Describes AutoSet Response settings (Standard/Soft) for gentler pressure changes.
Explains the intelligent system for controlling humidifier and heated tubing.
Details the recommended Auto setting for temperature and humidity control.
Explains manual settings for more control over temperature and humidity.
Explains how the temperature sensor controls delivered air temperature.
Details how to adjust humidity level for comfort.
Step-by-step guide for setting up the AirSense 11 device.
Lists and describes therapy settings like Mode, Pressure Range, and Set Pressure.
Details comfort settings including AutoSet response, Ramp Time, EPR, Climate Control, Tube Temp, and Humidity Level.
Covers patient view, smart stop/start, care check-in, and reminders.
Details settings for language, temperature units, restoring defaults, and erasing data.
Provides instructions on connecting an oxygen port to the device.
Step-by-step guide for disassembling the device and its components.
Provides daily and weekly cleaning instructions for components.
Guides on inspecting components like the humidifier tub, air tubing, and air filter.
Instructions on how to open the cover and replace the air filter.
Guides on reassembling the device after cleaning.
Details disassembling the cleanable humidifier tub, air tubing, and outlet connector.
Instructions for cleaning and disinfecting the device enclosure.
Cleaning instructions for air tubing, outlet connector, and cleanable HumidAir 11 tub.
Outlines high-level thermal and chemical disinfection procedures for components.
Guides on reassembling the outlet connector after disinfection.
Instructions for assembling the cleanable humidifier tub lid.
Instructions for connecting air tubing to the device and mask.
Explains cellular communication for automatic data transmission and remote settings.
Provides solutions for common problems like mask leaks, dry nose, and display issues.
Lists device error messages and their corresponding solutions.
Details operating and storage environmental conditions for the device.
Describes standard and hypoallergenic air filter materials and efficiency.
Explains EMC compliance and safe usage distances for RF equipment.
Illustrates the pneumatic flow path of the device with numbered components.
Lists displayed values, their ranges, accuracy, and resolution.
Specifies flow and pressure measurement accuracy according to standards.
Details dynamic pressure variation measurements for the device.
Lists measurement uncertainties for flow, static, and dynamic pressure.
Provides technical details for the Bluetooth module.
Lists specifications for the cellular module, including frequencies and RF power.
Lists humidifier specifications like heater plate and gas temperature.
Details humidifier performance metrics for different tubing and settings.