Ramp Time
Designed to make the beginning of therapy more comfortable, Ramp Time is the period during
which the pressure increases from a low start pressure to the prescribed treatment pressure.
You can set your Ramp Time to Off or between 5 to 45 minutes.
To adjust Ramp Time:
1. In My Options, turn the dial to highlight Ramp
Time and then press the dial.
2. Turn the dial to adjust the ramp time to your
preferred setting and press the dial to save the
change.
Ramp Down
Ramp Down is intended to make stopping therapy more comfortable by reducing your pressure over
a fixed 15 minute period. This option will only be available to you via your care provider.
To enable Ramp Down:
1. In My Options, turn the dial to highlight Ramp Down and then press the
dial.
2. Turn the dial to select On and then press the dial to save the change.
To start Ramp Down:
1. Press the Start/Stop button.
Note: If Confirm Stop is enabled, a message is displayed asking if you want to start Ramp Down.
Turn the dial to select Yes and then press the dial to start Ramp Down.
The Ramp Down icon and time remaining will be displayed at the bottom left of the screen.
Once Ramp Down is complete, the device will continue to run at low pressure. To stop therapy at
any time, press Start/Stop.
Humidity Level
The humidifier moistens the air and is designed to make therapy more comfortable. If you are
getting a dry nose or mouth, turn up the humidity. If you are getting any moisture in your mask, turn
down the humidity.
You can set the Humidity Level to Off or between 1 and 8, where 1 is the lowest humidity setting
and 8 is the highest humidity setting.

Other manuals for ResMed lumis series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ResMed lumis series and is the answer not in the manual?

ResMed lumis series Specifications

General IconGeneral
Device TypeNon-invasive ventilator
Pressure Range4-25 cm H2O
ModesCPAP, S, ST, T, iVAPS
Ramp Time0-45 minutes
HumidificationIntegrated heated humidifier
Data StorageSD card
Power SupplyAC 100-240V, 50-60Hz
Weight1.3 kg
Operating AltitudeUp to 2, 591 m
Heated TubingCompatible with ClimateLineAir heated tubing
ConnectivityBluetooth
DisplayLCD