System 8: Solar system with 1 store and afterheating with solid fuel boiler
The controller calculates the temperature difference between collector sensor
S1 and store sensor S2. If the difference is larger than or identical to the adjusted
switch-on temperature difference, the pump (R1) will be switched on and the store
will be loaded until the switch-off temperature difference or the maximum store
temperature is reached.
With another temperature differential function (S5 heat source/S3 heat sink), af-
terheating of the store with a solid fuel boiler can be carried out via another pump
(R3).
Hydraulic variant 1
Hydraulic variant 2
VBus
VBus
S5/V40
S4
S3
GND
S6
S7
Sensors
Relais
S2
S1
N
R3
R2
R1
L
R4
PWM A
0-10 V
PWM B
0-10 V
R4
N N N N
R3 R2 R1 L
1234
56789
10 11
332
2 2 3
2
R3
R1
S5
S3
S2
S1
Sensors
S1 Temperature collector 1 / GND
S2 Temperature store
base
2 / GND
S3 Temperature store top 3 / GND
S4 Free 4 / GND
S5 Temperature solid fuel
boiler
5 / GND
S6 Free S6
Relay
R1 Solar pump R1 / N / PE
R2 Free R2 / N / PE
R3 Loading pump solid
fuel boiler
R3 / N / PE
R4 Free R4 / R4