System 21: Solar system with east-/west collectors and 2 stores (valve logic)
The controller compares the temperatures at the collector sensors S1 and S5 to
the store temperature at sensor S2 and S3. If one of the measured temperature
differences is higher than the adjusted switch-on temperature differences, the cor-
responding pump (R1, R2) or both pumps will be activated and the corresponding
store will be loaded up to the adjusted maximum temperature via the valve (R3).
The priority logic effects prior loading of store 1.
Hydraulic variant 1
Hydraulic variant 3Hydraulic variant 2
Sensors
S1 Temperature collector 1 / GND
S2 Temperature store
base
2 / GND
S3 Free 3 / GND
S4 Temperature store
2 base
4 / GND
S5 Temperature collec-
tor 2
5 / GND
S6 Free S6
Relay
R1 Solar pump collector R1 / N / PE
R2
Solar pump collector 2
R2 / N / PE
R3 Valve solar circuit R3 / N / PE
R4 Free R4 /R4
R3
R2R1
S5
S4
S2
S1
VBus
VBus
S5/V40
S4
S3
GND
S6
S7
Sensors
Relais
S2
S1
N
R3
R2
R1
L
R4
PWM
A
0-10 V
PWM B
0-10 V
R4
N N N N
R3 R2 R1 L
1234
56789
10 11
32
222
3
3
3
Netz
Mains
Flow direction
when normally open