26
Starting the logging
Î Insert the MicroSD card into the slot.
Logging will start immediately.
Î Adjust the desired logging interval LOGI.
When LLOG is activated, data logging will stop if the capacity limit is reached. The
message CFULL will be displayed.
With non-linear logging (when LLOG is deactivated), the oldest data logged onto
the SD card will be overwritten as soon as the capacity limit is reached.
Completing the logging process
Î Select the menu item REMC.
Î After -REM is displayed remove the card from the slot.
Formatting the MicroSD card
Î Select the menu item FORM.
Î During the formatting process, --FORM will be displayed.
The content of the card will be deleted and the card will be formatted with the
FAT le system.
Storing controller adjustments
Î To store the controller adjustments on the MicroSD card, select the menu
item SAVE.
While the adjustments are being stored, rst WAIT, then SUCC will be indicated
on the display. The controller adjustments are stored as a .SET le on the MicroSD
card.
Loading controller adjustments
Î To load controller adjustments from an SD card, select the menu item LOAD.
The File selection window is indicated.
Î Select the desired .SET le.
While the adjustments are being loaded, rst WAIT, then SUCC will be indicated
on the display.
Messages possible Description
FSYS File system error
CTYP Card type is not supported
WRIT Error during writing
NOCRD No card in slot
LOGG Logging is possible
WRITP Card is write-protected
CFULL Card full
RTIME Remaining logging time in days
REMC Safely remove card command
--REM Card is being removed
FORM Formatting SD card command
--FORM Formatting in progress
LOGI Logging interval in min
LLOG Linear logging
WAIT Wait
SUCC Successful
Note:
Because of the increasing size of the data packets, the remaining logging
time does not decrease linearly. The data packet size can increase, e. g. with
the increasing operating hours value.