Voxnet 219 Operation
8
Environmental conditions in the rack
In the case of a rack installation, you
must ensure that the inside temperature
of the rack does not exceed +40°C /
+104°F. If necessary, the rack must be
actively cooled using a fan.
The Voxnet amplifier itself is fitted with
an active fan control and controls its
own inner temperature. Cool air is
sucked in at the front of the amplifier,
drawn through the unit and blown out of
the slots at the back. For this reason,
cool air must be able to get to the front
of the amplifier to be drawn in, even if
the rack door is closed. Multiple trays
can be mounted underneath each other
in the rack, without having to leave any
gaps between them.
Stack of 8 Voxnet 219s
Use of switch-on current limiter
In the case of the installation of more
than
4 Voxnet 219s per secured 16A
circuit, Revox recommends the use of a
switch-on current limiter.
This provides effective protection
against a mains circuit breaker being
tripped during switch-on following a
power outage or an overnight shutdown.