TM049 27L Continuous Flow Service Instructions
REV AL Issued April 2019
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed “uncontrolled”.
49
Fault Finding Tests 10 & 12 - 14
Tests 10 and 12
Test 10: Conduct test with water flowing.
Using a multimeter set on the DC volts scale,
measure the voltage between 1 Red and 2 Black
at terminal P whilst plugged into PCB.
Normal voltage is between DC1.5 and 14.0V.
Test 12:
Using a multimeter set on the ohms scale, measure
the resistance between 1 Red and 2 Black at
terminal P whilst unplugged from the PCB.
Normal resistance is between 40 ohms and 80
ohms.
Test 13
Test 14
Conduct test with flame present.
Using a multimeter set on the AC volts scale,
measure the voltage between W1 at terminal U
and earth.
Normal voltage should be 1 - 100VAC.
Unplug multi-pin connector from terminal T on
control PCB and using a multimeter set on the
kilo-ohms scale, measure the resistance of the
Over Heat Limiter assembly.
Normal resistance should be between 50 - 500
kilo-ohms.
K
BK R YBR G W
1 2 3 4 5 6 87
R
BK
BK
R
BL
4
2
7
6
5
Y
W
1
2
3
4
BL
O
W
BR
R
BK
4
3
2
1
8
7
6
5
N
O
9
Y
G
5
6
1
2
3
4
SW1 SW2
P
V
3
2
1
T
1
2
S
3
2
1
1
U
1
1
1
2
3
S
2
1
T
1
U
1
2
3
V

Related product manuals