EasyManua.ls Logo

Rheem ECONET RP2036BJVCA User Manual

Rheem ECONET RP2036BJVCA
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VARIABLE SPEED R-410A
HEAT PUMP OUTDOOR UNITS
INSTALLATION INSTRUCTIONS
92-105074-14-01 (02/18)
Printed in USA
[ ] indicates metric conversions.
Do not destroy this manual.
Please read carefully and
keep in a safe place for future
reference by a serviceman.
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS UNIT.
READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
ATTEMPTING INSTALLATION
OR OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY
RESULT IN IMPROPER
INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
(-)P20 (20 SEER) EQUIPPED WITH
ECONET™ COMMUNICATIONS
WARNING:
RECOGNIZE THIS SYMBOL
AS AN INDICATION OF
IMPORTANT SAFETY
INFORMATION
67$
Enabled

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rheem ECONET RP2036BJVCA and is the answer not in the manual?

Rheem ECONET RP2036BJVCA Specifications

General IconGeneral
BrandRheem
ModelRP2036BJVCA
TypeHeat Pump
Energy Efficiency Ratio (EER)12.5
RefrigerantR-410A
Phase1
Cooling Capacity36000 BTU/h
Voltage208-230V
Tonnage3 Ton

Summary

Important Safety Information

Installation

System Start-Up and Refrigerant Charging

Normal Sequence of Operation

Components & Controls

EcoNet™ Variable Speed Outdoor Control (VSODC)

Overview of the VSODC features, connections, and menus.

Electronic Expansion Valve

Function and operation of the electronic expansion valve.

Active System Protection Features

High Discharge Temperature

Protection against high discharge temperatures.

High Discharge Pressure

High discharge pressure protection and lockout conditions.

Low Suction Pressure/ Loss of Charge

Protection against low suction pressure or loss of charge.

Compressor Shut-Down Sequence for High or Low Refrigerant Pressure Fault

Sequence for compressor shutdown due to pressure faults.

Sensor Failure Default Operation

Default system operation when a sensor fails.

Diagnostics & Troubleshooting

Fault Recall Procedure

How to access stored fault codes.

Compressor/Fan Motor Test Mode

Using test mode to check compressor and fan operation.

Status and Diagnostic Codes

Descriptions of VSODC status and diagnostic codes.

Active Protection Fault Details

Details on specific active protection faults.

Electrical Checks Flowchart

Flowchart for electrical system checks.

Cooling Mechanical Checks Flowchart

Flowchart for cooling system mechanical checks.

Wiring Diagram