TM090 12-26 Series II CFGWH Service Instructions
REV AB Issued February 2019
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed “uncontrolled
DIAGNOSTIC TEST POINTS
Refer to wiring diagram, page 8, for connector and wiring positions.
Test
Point
Measuring Point
Normal Condition
Items Under Test
Connector
Wire Nº
& colour
1
A
BL2 BR1
AC 207V 264V
Main Power
2
I
W2 W3
40 kilo-ohms 500 kilo-ohms
Overheat Limiter
3
F
BL17 BK16
DC 2V 5V(Pulse) *1
More than 1310 pulse/min
Water Flow Sensor pulse signal
R18 BK16
DC 7V 15V
Water Flow Sensor voltage
4
L
BK3 R1
DC 5V 50V
Fan Motor
O4 BK3
DC 9V 15V
Y5 BK3
DC 4V 10V(Pulse) *1
More than 4800 pulse/min
Fan Motor pulse signal
5
F
W10 BK9
@ 20ºC 10.3 kilo-ohms
@ 40ºC 4.9 kilo-ohms
Water Inlet Thermistor
6
F
G14 BK9
@ 20ºC 10.3 kilo-ohms
@ 40ºC 4.9 kilo-ohms
Heat Exchanger Thermistor
7
F
BL15 BK9
@ 20ºC 10.3 kilo-ohms
@ 40ºC 4.9 kilo-ohms
Hot Water Outlet Thermistor
8
F
BL11 BK9
@ 5ºC 12.5 kilo-ohms
@ 20ºC 6.3 kilo-ohms
Ambient Air Thermistor
9
J
R1 Earth
AC 1V 170V *2
Flame Sensor detecting flame
K
GY1 Earth
AC 1V 170V *2
10
I
R6 - BK5
DC 1.5V 14V
40 ohms 80 ohms
Proportional Gas Flow Regulating
11
I
Y12 BK11
DC 9V 15V
17 ohms 27 ohms
Gas Inlet Solenoid Valve
12
I
O9 BK11
DC 9V 15V
Igniter
13
I
R8 BK11
DC 9V 15V
14 ohms 23 ohms
Solenoid Valve 2
14
K
GY1 - Earth
AC 1V 170V *2
Flame Sensor detecting flame
15
F
W2 BK1
DC 8V 16V
Water Volume Control Motor position
switch
R7 BK1
DC 8V 16V
G3 BK1
Less than DC 1V (Limiter ON)
DC 4V 6V (Limiter OFF)
16
I
Y12 BK11
DC 9V 15V
17 ohms 27 ohms
Gas Inlet Solenoid Valve
BL10 BK11
DC 9V 15V
14 ohms 23 ohms
Solenoid Valve 1
R8 BK11
DC 9V 15V
14 ohms 23 ohms
Solenoid Valve 2
W7 BK11
DC 9V 15V
14 ohms 23 ohms
Solenoid Valve 3
R6 BK5
DC 1.5V 14.0V
40 ohms 80 ohms
Proportional Gas Flow Regulating
J
R1 - Earth
AC1V 170V *2
Flame Sensor detecting flame
K
GY1 - Earth
AC1V 170V *2
NOTES:
*1: Approximate reading measured by digital multimeter on DC range.
*2: Approximate reading measured by digital multimeter on AC range.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem II Series and is the answer not in the manual?

Rheem II Series Specifications

General IconGeneral
CategoryWater Heater
SeriesII Series
TypeElectric
Energy Factor0.95
Voltage240V
Wattage4500-5500W
Warranty6 years
Diameter22 inches
Capacity40-80 gallons

Related product manuals