TM090 12-26 Series II CFGWH Service Instructions
REV AB – Issued February 2019
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed “uncontrolled”
DIAGNOSTIC TEST POINTS
Refer to wiring diagram, page 8, for connector and wiring positions.
40 kilo-ohms – 500 kilo-ohms
Water Flow Sensor pulse signal
Water Flow Sensor voltage
Heat Exchanger Thermistor
Hot Water Outlet Thermistor
Flame Sensor detecting flame
Proportional Gas Flow Regulating
Flame Sensor detecting flame
Water Volume Control Motor position
switch
Less than DC 1V (Limiter ON)
Proportional Gas Flow Regulating
Flame Sensor detecting flame
NOTES:
*1: Approximate reading measured by digital multimeter on DC range.
*2: Approximate reading measured by digital multimeter on AC range.