At the time when air conditioner is switched from Cooling mode
to Heating mode, a compressor is stopped, and a 4-way valve is
switched in 3 minutes later after a compressor stopped.
14. 4-WAY VALVE EXTENSION SELECT
15. AUTO RESTART
The compressor won't enter operation status for 3 minutes
after a compressor is stopped, even if any operation is given.
13. PREVENT TO RESTART FOR 3 MINUTES ( 3 MINUTES ST )
04-29
If power is interrupted by blackout, etc. in operation,
the operation contents at that time are memorized.
And when power is recovered, operation is automatically
resumed with the memorized operation contents.
When power is interrupted and recovered during timer operation,
timer operation is canceled, but only setting time is memorized.
Operation contents memorized
Operation mode
Set temperature
Set airflow
ECONOMY
Air flow direction (Swing setting)
Energy saving setting
Each central setting