EasyManua.ls Logo

Rheem RP1748HJVXA - Fan Performance; Fan Performance Curve

Rheem RP1748HJVXA
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Fan performance
5-1. Fan performance curve
¢ Model: RHMV2421MNACJA
*: The air volume is automatically adjusted near the target air volume by the function of automatic air
volume adjustment. (Within the SP range of 0.1—1.0 inWG)
¢ Model: RHMV3021SNACJA
0
0.2 (50)
0.4 (100)
0.6 (150)
0.8 (200)
1.0 (250)
1.2 (300)
1.4 (350)
0
(500) (1,000) (1,478) (1,500) (2,000)
294 589 870
883 1,177
Airflow (CFM [m3/h])
External static pressure (inWG [Pa])
Fan performance curve of
Maximum static pressure
Fan performance curve of
Minimum static pressure
Air volume of the High-notch
(The static pressure
range of 0.1—1.0 inWG) *
Air volume of the Quiet-notch
(The static pressure range of
0.1—1.0 inWG)
0.1 (25)
*: The air volume is automatically adjusted near the target air volume by the function of automatic air
volume adjustment. (Within the SP range of 0.1—1.0 inWG)
- 13 -
5-1. Fan performance curve 5. Fan performance
DUCT TYPE
RHMV2421-4821*NACJ
A
DUCT TYPE
RHMV2421-4821*NACJ
A