10. Electrical characteristics
Item Unit
Model name
RP1724HJVXA RP1730HJVXA
Power
supply
Voltage V 208/230 V~
Frequency Hz 60
MCA *1 A 20.8
Starting current A 9.6 11.5
Wiring spec.
*
2
MAX. CKT. BKR *
3
A 30
Power cable AWG 16—14
Connection
cable *
4
Size AWG 20—16
Limited wiring
length
ft (m) 167 (51)
Item Unit
Model name
RP1736HJVXA RP1748HJVXA
Power
supply
Voltage V 208/230 V~
Frequency Hz 60
MCA *1 A 39.9
Starting current A 20.1
Wiring spec.
*
2
MAX. CKT. BKR *
3
A 40
Power cable AWG 8
Connection
cable *
4
Size AWG 14
Limited wiring
length
ft (m) 246 (71)
*1: Minimum Circuit Ampacity (Calculation based on UL1995)
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Maximum Circuit Breaker
*4: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
- 89 -
10. Electrical characteristics
OUTDOOR UNIT
RP1724-1748HJVXA
OUTDOOR UNIT
RP1724-1748HJVXA