EasyManua.ls Logo

Rheem RP1748HJVXA - Safety Devices

Rheem RP1748HJVXA
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Safety devices
Type of protection Protection form
Model
RP1724HJVXA RP1730HJVXA
Circuit protection
Current fuse (Filter PCB) 250 V, 5 A × 2
Current fuse (Main PCB) 250 V, 3.15 A × 2
Fan motor protection Thermal protection
Activate
302
+27
-18
°F (150
+15
-10
°C)
Fan motor stop
Reset
248
+27
-18
°F (120
+15
-10
°C)
Fan motor restart
Compressor
protection
Terminal protection
program
(Compressor temp.)
Activate
226 °F (108 °C)
Compressor stop
Reset
176 °F (80 °C)
Compressor restart
Thermal protection
program
(Discharge temp.)
(COOL or DRY
mode)
Activate
230 °F (110 °C)
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection
program
(Outdoor temp.)
Activate
Reset
High pressure
protection
Pressure switch
Activate
4.2±0.1 MPa
Compressor stop
Reset
3.2±0.15 MPa
Compressor restart
Type of protection Protection form
Model
RP1736HJVXA RP1748HJVXA
Fuse (Filter PCB)
AC 250 V, 5 A
AC 250 V, 10 A × 2
Protector (Filter PCB) AC 500 V, 45 A
Fuse (MAIN PCB) AC 250 V, 3.15 A × 2
Fuse (INV PCB) AC/DC 400 V, 5 A
Fan motor
protection
Thermal protection
Activate
239±27 °F (115±15 °C)
Fan motor stop
Reset
158 °F (70 °C)
Fan motor restart
Compressor
protector
Over current protection
Temperature
protection
Activate
226.4 °F (108 °C)
Compressor stop
Reset
176 °F (80 °C)
Compressor restart
Thermal protection
program
(Discharge temp.)
Activate
230 °F (110 °C)
Compressor stop
Reset
After 3 minutes
and 230 °F (110 °C) less than
Compressor restart
High pressure protection
Activate 580 psi (4.0 MPa)
Reset 471 psi (3.25 MPa)
- 90 -
11. Safety devices
OUTDOOR UNIT
RP1724-1748HJVXA
OUTDOOR UNIT
RP1724-1748HJVXA

Table of Contents

Other manuals for Rheem RP1748HJVXA