Loading...
INSTALLATION – GENERAL
16
DIMENSIONS AND TECHNICAL DATA – XS MODELS
Fitting connections: O = outlet (red), I = inlet (blue), Dr = anode
All dimensions are in mm
Model
XS-20 XS-30
Nominal Storage Capacity Litres
20 30
Voltage AC Volts
220-240 220-240
Frequency Hz 50-60 50-60
Dimensions
Mounting holes to water connections A mm 221 234
Mounting holes to right hand jacket B mm 208 235
Spacing between mount holes C mm 300 326
Depth D mm 278 318
Inlet connection to right hand jacket F mm 304 345
Height including fittings G mm 306 346
Height H mm 287 330
Width W mm 674 760
Water connection from wall I/O mm 143 163
Thermostat setting (factory setting) °C 70 70
Pressure Relief Valve Setting kPa 800 800
Maximum inlet water pressure kPa 640 640
Water inlet/outlet connections
G 1/2 B G 1/2 B
Approx. Weight empty kg 13 17
Approx. Weight full kg 33 47
All models are suitable for indoor installation only, ingress protection = IP24.
Technical data is subject to change.