1 - KING operator
2 - Tuned aerial
3 - Flashing lamp
4 - Key selector
5 - Photoelectric cells (external)
TECHNICAL FEATURES
KING is a series of linear irreversible operators, suitable for
opening gates with a leaf length of up to 4,5 metres (Fig.1).
The KING operators use mechanical stoppers, thus avoiding
the need for electrical limit switches.
On reaching the travel limit, the motor continues to operate for
a few seconds, until the timer of the control unit (or the
ENCODER in the PLUS version) cuts in.
Measurements in mm
KING L
L=1020
L1=945
L2=470
KING L=888 L1=815 L2=340
1 S / Encod M
2 +
3 GND
* ONLY
KING PLUS
*
1 V
2 W
3U
Encoder
1
GG
BB
SYSTEM LAY-OUT
TECHNICAL DATA
M
ax. leaf length
M
ax. leaf weight
Max. travel
A
verage opening time
O
perating speed
Thrust force
E
EC Power supply
Motor capacity
Power absorbed
C
apacitor
Power supply
Motor capacity
P
ower absorbed
Capacitor
Power supply
M
otor capacity
Power absorbed
C
apacitor
No. normative cycles 230V
No. normative cycles 220V
No. normative cycles 120V
No. of daily operations suggested
Service
No. guaranteed consecutive cycles
Grease
Weight of electroreducer
Noise
Volume
Operating Temperature
Protection
m
. 3,5* 4,5*
k
g 400 500
mm 345** 475**
s
. 14÷27 29÷38
m
/s. 0,0125
N
1800
2
30V~ 50Hz
W 290
A
1
,2
µF
10
220V~ 60Hz
W
2
25
A
1,04
µF8
120V~ 60Hz
W
255
A 2,3
µF
35
17 - 14s/2s 10 - 33s/2s
31 - 14s/2s 20 - 33s/2s
29 - 14s/2s 11 - 35s/2s
150
60%
20/14s 15/33s
Bechem - RHUS 550
kg 10 14
db <70
m
3
0,0184 0,0211
°C -10 ÷ +55°C
IP 447
KING KING L
**
With incorporated mechanical stop that cuts in during opening. - If
the mechanical stop is used during closing (optional), the maximum
travel is reduced by 50 mm.