Main SP Tables-1
D146/D147/D148/D149/D150 2-12 System Maintenance Section
Have pressuring time for side fence of one action bypass tray (for truing up the
paper) When making this value larger than necessary, side effects might occur
like thin paper buckling.
035
Postcard_SEF/Envelope Choukei 3_SEF Th *ENG
[0.000 to 3.300
/ 0.000 /
0.001V/step]
Adjoining paper width threshold with side fence position sensor of one action
bypass tray.
1009
[Initial Operation Setting]
Switches 1: ON 0: OFF of register back rush removal when recovering form
sleep mode. With default setting, this is OFF prior less noise.
001
Registration Gear Backlash
Cut
*ENG
[0 or 1 / 0 / 1/step]
0:OFF
1:ON
1101 [Reload Permit Setting]
001
Pre-rotation Start Temp. *ENG
[0 to 200 / 0 /
1deg/step]
Do not change. Temperature for when to switch form no rotate heating to stand up
heating.
002
Reload Target Temp.:Center *ENG
[0 to 190 /
D146:123,
D147:123,
D148:141,
D149:157,
D150:157 /
1deg/step]
Do not change. Reload permission target temperature: center