Main SP Tables-1
D146/D147/D148/D149/D150 2-22 System Maintenance Section
014
Temp.:Lower Delta:End:Sp.2 *ENG [0 to 200 / 5 / 1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
edge: special mode 2
015
Temp.:Upper
Delta:Center:Sp.2
*ENG [0 to 200 / 15 / 1deg/step]
Do not change. Paper feed start permission temp. upper diff from target temp. :
center: special mode 2
016
Temp.:Upper Delta:End:Sp.2 *ENG [0 to 200 / 15 / 1deg/step]
Do not change. Paper feed start permission temp. upper diff from target temp. :
edge: special mode 2
017
Temp.:Lower
Delta:Press:Sp.2
*ENG [0 to 200 / 100 / 1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
pressure: special mode 2
018
Rotation Time:Sp2 *ENG [0 to 100 / 0 / 1sec/step]
Do not change. Paper feed permission setting rotate before decision time:
special mode 2
019
Feed Permit Time *ENG [0 to 100 / 60 / 1sec/step]
Do not change. Setting time between Before paper feed action form paper feed
permission.
020
Temp.:Lower Delta:Center *ENG
[0 to 200 / D146:40, D147:40,
D148:52, D149:40, D150:40 /
1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
center
021
Temp.:Lower Delta:End *ENG
[0 to 200 / D146:40, D147:40,
D148:52, D149:40, D150:40 /
1deg/step]
Do not change. Paper feed start permission temp. lower diff from target temp. :
edge